AFS10D | Duplex Field Control Unit | Yokogawa

AFS10D | Duplex Field Control Unit | Yokogawa

Formulir produk

Yokogawa AFS10D Duplex Field Control Unit Configured for deterministic execution of regulatory control loops in CENTUM VP and CENTUM CS... Baca selengkapnya

SKU: AFS10D
Negara asal: JAPAN

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Yokogawa AFS10D Duplex Field Control Unit

    Configured for deterministic execution of regulatory control loops in CENTUM VP and CENTUM CS 3000 platforms, the Yokogawa AFS10D (base model AFS10D Field Control Unit) provides direct physical and electrical interfacing between Remote I/O nodes and the Vnet/IP control network.

    Suffix Breakdown & Model Matrix

    Code Specification Description
    Model AFS10D Duplexed Field Control Unit (for RIO)
    Suffix Codes -S Standard type
      5 100 - 120 V AC Power Supply
      6 220 - 240 V AC Power Supply
      7 24 V DC Power Supply
      1 Vnet/IP Type / Dual-redundant

    Hardware Specifications

    Parameter Specification
    Brand Yokogawa
    Origin Japan
    Weight 9 kg
    Dimensions 482.6 mm x 310 mm x 265 mm (19-inch rack)
    Operating Temp 0 to 50 degC
    Power Consumption 410 VA (max, AC); 8 A (24 VDC)
    Input Voltage 100-120 VAC, 220-240 VAC, 24 VDC
    Redundancy Dual-redundant CPU, Power, Bus
    Network Interface Vnet/IP / VL net

    FOUNDATION Fieldbus & Profibus PA Connectivity

    The AFS10D interfaces with field devices via Remote I/O nodes supporting FOUNDATION Fieldbus H1 and Profibus PA protocols. The control bus maintains deterministic cyclic data exchange with a 50 ms update rate. Channel-to-channel isolation is enforced at 500 VDC to suppress transient noise coupling from field wiring. Cold junction compensation is applied internally for connected thermocouple inputs through the associated I/O modules.

    Frequently Asked Questions

    Q: What is the maximum inrush current when hot-swapping a power supply module?

    A: The redundant power supply allows hot-swap replacement with an inrush current not exceeding 30 A for 50 ms. Verify voltage compatibility before insertion.

    Q: Is battery-backed memory retained during complete power loss?

    A: Yes. Main memory contents are preserved via a lithium battery backup, maintaining volatile data during outages. Battery replacement requires a scheduled shutdown.

    Q: What is the failover time between the active and standby CPUs?

    A: Bumpless transfer occurs within 10 ms. Output states remain unchanged during the transition.

    Field Installation Guidelines

    Mount the unit in a standard 19-inch rack with 150 mm rear clearance for bus cabling. Ground the chassis using a 5/16 inch ring terminal connected to the plant earth grid. Terminate all shield drains at the controller end only. Torque power terminals to 1.2 Nm. Set RIO bus termination switches to ON for the final physical node.

    Spesifikasi

    • Merek: Yokogawa

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun