ABB TU831V1 Extended Module Termination Unit
Configured for field termination and ModuleBus distribution in the ABB S800 I/O system, the ABB TU831V1 3BSE013235R1 (TU831V1 Extended Module Termination Unit) provides physical connections for compatible digital I/O modules. It supports up to 8 I/O channels, with a maximum rated voltage of 250 V and maximum current of 3 A per channel.
Hardware Specifications
Parameter
Specification
Model
TU831V1
Article Number
3BSE013235R1
Brand
ABB
Product Type
Extended Module Termination Unit
Series
S800 I/O
Origin
Not specified in supplied data
Weight
0.22 kg (0.48 lbs)
Dimensions
126 mm W x 64 mm D x 110 mm H
Installed Width
120.5 mm edge to edge
Channels
Up to 8 I/O channels
Process Connections
16 terminals, 2 terminals per channel
Maximum Rated Voltage
250 V
Maximum Current per I/O Channel
3 A
Connection
Terminal block
I/O Configuration
Single
Compatible I/O Modules
DI820, DI821, DO820, DO821
Mounting
Standard DIN rail
Mounting Direction
Both directions
ModuleBus Distribution
To the I/O module and next MTU
Address Generation
Position signal shifting to the next MTU
Wire Size, Solid
0.2 - 6 mm2
Wire Size, Stranded
0.2 - 4 mm2, 24 - 10 AWG
Recommended Terminal Torque
0.5 - 0.6 Nm
Wire Stripping Length
7 mm
Dielectric Test Voltage
2000 V AC
Operating Temperature
0 to +55 deg C (+32 to +131 deg F)
Approved Operating Temperature
+5 to +55 deg C
Storage Temperature
-40 to +70 deg C (-40 to +158 deg F)
Relative Humidity
5 to 95 %, non-condensing
Pollution Degree
Degree 2, IEC 60664-1
Corrosion Protection
ISA-S71.04: G3
Protection Class
IP20 according to IEC 60529
Mechanical Conditions
IEC/EN 61131-2
EMC
EN 61000-6-4, EN 61000-6-2
Overvoltage Categories
IEC/EN 60664-1, EN 50178
Equipment Class
Class I according to IEC 61140
CE Mark
Yes
Electrical Safety
EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201
Marine Certifications
ABS, BV, DNV-GL, LR
RoHS
EN 50581:2012
WEEE
Directive 2012/19/EU
ABB S800 I/O ModuleBus and I/O Density
The TU831V1 distributes the ModuleBus from the mounted I/O module toward the next MTU. It also shifts outgoing position signals so the following MTU receives the corresponding module address position.
The eight-channel configuration provides a compact termination arrangement for compatible S800 I/O modules. Each channel uses two process terminals, giving 16 process connections for the complete eight-channel arrangement.
The MTU does not function as an independent I/O processing module. Instead, it provides the mechanical, electrical, termination, and ModuleBus interface required by the supported I/O modules. Therefore, module compatibility must be checked before installation.
Frequently Asked Questions
Q: How many I/O channels does the ABB TU831V1 support? A: The TU831V1 supports up to 8 I/O channels and provides 16 process connections, with two terminals assigned to each channel.
Q: What I/O modules are specified for use with the TU831V1? A: The supplied data identifies DI820, DI821, DO820, and DO821 as compatible I/O modules.
Q: What is the maximum electrical rating per I/O channel? A: Each I/O channel has a maximum rated voltage of 250 V and a maximum current rating of 3 A.
Field Installation Guidelines
Mount the TU831V1 on a suitable standard DIN rail and engage the mechanical latch fully.
Verify the MTU orientation and terminal accessibility before connecting field wiring.
Confirm that the selected I/O module is one of the specified compatible types.
Keep field wiring separated from high-energy switching conductors where the installation requires signal-noise control.
Route signal wiring to minimize unnecessary parallel runs with power conductors.
Use conductor sizes within the specified 0.2 - 6 mm2 solid or 0.2 - 4 mm2 stranded range.
Apply the specified 0.5 - 0.6 Nm terminal torque during wiring.
Strip approximately 7 mm of insulation from conductors before termination.
Verify protective earth arrangements according to the applicable installation standard because the equipment is Class I.
Inspect terminal connections before energization and verify that no conductor strands contact adjacent terminals.
Confirm the ModuleBus path and MTU position before commissioning the connected I/O module.
Do not exceed the specified 250 V maximum voltage or 3 A maximum current per I/O channel.
Maintain the specified environmental limits during installation and operation.