8C-TAIXA1 | Honeywell Series 8 Analog Input I/O Termination Assembly

8C-TAIXA1 | Honeywell Series 8 Analog Input I/O Termination Assembly

Formulir produk

Honeywell 8C-TAIXA1 Series 8 Analog Input I/O Termination Assembly Configured for analog field signal termination in Honeywell Experion PKS and... Baca selengkapnya

SKU: 8C-TAIXAI
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell 8C-TAIXA1 Series 8 Analog Input I/O Termination Assembly

    Configured for analog field signal termination in Honeywell Experion PKS and Experion LX Series 8 control systems, the Honeywell 8C-TAIXA1 (8C-TAIXA1 Analog Input I/O Termination Assembly) provides direct physical and electrical connection between field wiring and Series 8 analog input modules.

    Hardware Specifications

    Parameter Specification
    Model 8C-TAIXA1 (51307127-175)
    Brand Honeywell
    Origin USA
    Dimensions 6 inch mounting format
    Operating Temp 0 deg C to +60 deg C
    Power Consumption Field loop power distribution only; module consumption not specified
    System Architecture Honeywell Series 8 / Experion PKS / Experion LX
    Module Type Analog Input I/O Termination Assembly
    Input Channels 16 single-ended analog input channels
    Signal Type 4-20 mA current input
    Field Device Support 2-wire and self-powered transmitters
    Redundancy Type Non-redundant
    Coating Type Conformal coated
    Environmental Rating Class G3 harsh environment protection
    Nominal Voltage Rating 24 VDC
    Storage Temperature -40 deg C to +85 deg C
    Humidity Range 5% to 95% RH non-condensing
    Hazardous Area Certification Class I, Division 2, Groups A, B, C, D; Class I, Zone 2

    Process Control Analog Signal Interface

    The Honeywell 8C-TAIXA1 supports Series 8 analog input signal termination through a dedicated field wiring interface. The assembly routes 16 single-ended analog signals to compatible Series 8 Analog Input Modules, including the 8C-PAINA1 module.

    Furthermore, the termination assembly maintains organized field connections and supports transmitter loop wiring for 4-20 mA process instruments. The conformal coating protects circuit surfaces against moisture, airborne contaminants, and corrosive industrial environments.

    The IOTA design separates field wiring access from the electronic input module connection point. Therefore, maintenance personnel can replace associated I/O modules while keeping field wiring connections installed.

    Frequently Asked Questions

    Q: Does the 8C-TAIXA1 provide analog signal conversion?

    A: No. The 8C-TAIXA1 is an I/O Termination Assembly. It provides field wiring termination and signal routing, while signal processing is performed by the connected Series 8 Analog Input Module.

    Q: Can the 8C-TAIXA1 support redundant operation?

    A: No. The 8C-TAIXA1 is specified as a non-redundant termination assembly. Redundancy functions depend on the connected controller and I/O architecture configuration.

    Q: What installation practices are required for 4-20 mA field wiring?

    A: Field cables should use proper shielding, grounding, and separation from high-voltage power conductors. The shield termination method should follow the plant grounding standard and Honeywell installation requirements.

    Field Installation Guidelines

    Install the 8C-TAIXA1 on the designated Series 8 mounting channel and verify mechanical alignment before connection.

    Connect field transmitter wiring according to the approved Honeywell terminal assignment documentation. Maintain cable segregation between analog signal wiring and high-energy switching circuits to reduce electromagnetic interference.

    Terminate cable shields according to the site grounding philosophy. Avoid multiple shield grounding points unless required by the control system design.

    Before commissioning, verify each analog input loop for correct polarity, continuity, and transmitter power distribution. Confirm that the connected Series 8 Analog Input Module recognizes all configured channels.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun