Bently Nevada 330880-16-00-075-00-02 PROXPAC XL Proximity Transducer Assembly The Bently Nevada 330880-16-00-075-00-02, also cataloged as the 330880 PROXPAC XL Proximity... Baca selengkapnya

SKU: 330880-16-0-75-00-02
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 330880-16-00-075-00-02 PROXPAC XL Proximity Transducer Assembly

    The Bently Nevada 330880-16-00-075-00-02, also cataloged as the 330880 PROXPAC XL Proximity Transducer Assembly, operates as a dedicated hardware component for non-contact shaft displacement measurement within Bently Nevada vibration monitoring systems.

    Hardware Specifications

    Parameter Specification
    Model 330880-16-00-075-00-02
    Brand Bently Nevada
    Product Type PROXPAC XL Proximity Transducer Assembly
    Origin USA
    Weight Approximately 5.3 kg
    Operating Temp -52 deg C to +100 deg C
    Power Consumption Powered by -17.5 VDC to -26 VDC supply without safety barriers
    Probe Diameter 8 mm
    Probe Type 3300 XL 8 mm Proximity Probe
    Probe Penetration Length 75 mm
    Mounting Thread 3/4-14 NPT
    Housing Material Glass and conductive fiber-reinforced Polyphenylene Sulfide (PPS)
    Linear Range 0.25 mm to 2.3 mm
    Recommended Gap Setting 1.27 mm
    Scale Factor 7.87 V/mm (200 mV/mil) +/-5% nominal
    Frequency Response 0 Hz to 10 kHz (+/-3 dB)
    Output Resistance 50 ohm nominal
    Probe DC Resistance 50 ohm nominal
    Ingress Protection IP66 / Type 4X

    Eddy-Current Probe Scaling and Rotor Dynamics Monitoring

    The 330880-16-00-075-00-02 assembly uses eddy-current probe scaling principles to convert shaft displacement into proportional electrical signals. The integrated 3300 XL 8 mm probe maintains a nominal scale factor of 7.87 V/mm, allowing vibration and axial position systems to process dynamic shaft movement data.

    Additionally, the assembly supports rotor dynamics monitoring by providing non-contact measurement of rotating shaft position changes. The system evaluates vibration displacement, shaft motion, and mechanical clearance behavior through continuous proximity signal output.

    The probe gap voltage requires proper validation during installation. Bently Nevada monitoring systems typically verify the operating gap condition around the -10 VDC target range to confirm correct probe positioning and signal linearity.

    Frequently Asked Questions

    Q: Does the 330880-16-00-075-00-02 require a separate Proximitor sensor housing?
    A: No. The PROXPAC XL assembly integrates the probe, cable, and Proximitor electronics into a single enclosure.

    Q: What signal measurement principle does this assembly use?
    A: The assembly uses an eddy-current proximity measurement principle to detect shaft displacement without physical contact.

    Q: Can the unit connect directly to Bently Nevada 3500 monitoring systems?
    A: Yes. The assembly provides proximity measurement signals compatible with Bently Nevada machinery protection monitoring architectures when the system configuration matches the required input characteristics.

    Field Installation Guidelines

    Install the 330880-16-00-075-00-02 using the specified 3/4-14 NPT mounting interface and ensure proper mechanical alignment between the probe tip and rotating shaft surface.

    Verify the probe gap before operation and confirm the electrical output remains within the expected operating range. Maintain correct cable routing to reduce electromagnetic interference from high-current power conductors.

    Connect the housing grounding path according to site grounding practices. Use proper shielding termination methods to minimize signal noise during vibration and displacement measurement.

    Inspect the probe tip, mounting thread, and cable condition before commissioning. Avoid mechanical impact on the PPS housing and maintain environmental sealing when installing the assembly in outdoor or contaminated areas.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun