Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

200200-02-02-CN Bently Nevada ProTIM-R DIN Rail Mount Module

200200-02-02-CN Bently Nevada ProTIM-R DIN Rail Mount Module

Formulir produk

Bently Nevada 200200-02-02-CN ProTIM-R DIN Rail Mount Module Configured for dual thermocouple signal conditioning in the Trendmaster Pro online condition... Baca selengkapnya

SKU: 200200-02-02-CN
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 200200-02-02-CN ProTIM-R DIN Rail Mount Module

    Configured for dual thermocouple signal conditioning in the Trendmaster Pro online condition monitoring system, the Bently Nevada 200200-02-02-CN (200200 ProTIM-R DIN Rail Mount Module) provides direct physical and electrical execution for temperature measurement channels.

    Hardware Specifications

    Parameter Specification
    Model 200200-02-02-CN
    Brand Bently Nevada
    Origin United States
    Operating Temp -25 deg C to +85 deg C
    Power Consumption Not specified
    Product Type Processor Transducer Interface Module (ProTIM-R)
    System Platform Trendmaster Pro Online Condition Monitoring System
    Mounting Type DIN Rail Mount
    Number of Channels 2 independent configurable channels
    Channel AA Input K-Type Thermocouple via 200125 temperature transducer
    Channel BB Input K-Type Thermocouple via 200125 temperature transducer
    Process Voltage Input Range +1 VDC to +5 VDC
    Process Current Input Range +4 mA to +20 mA
    Temperature Measurement Range -18 deg C to +204 deg C
    Temperature Accuracy +/-8 deg C including ProTIM-R, thermocouple, and lead wire error
    Temperature Resolution 0.07 deg C
    Maximum Lead Wire Length 6 meters
    Maximum Temperature Ramp Rate +/-0.5 deg C/min
    OK Operating Range -31 deg C to +213 deg C
    Storage Temperature -40 deg C to +100 deg C
    Humidity Rating 100% condensing on exposed surfaces
    Hazardous Area Approval NEPSI and ATEX/IECEx option

    Eddy-Current Signal Scaling and Temperature Channel Processing

    The ProTIM-R module processes field transducer signals through dedicated input conditioning circuits. Moreover, the dual-channel architecture allows independent measurement handling for two temperature inputs connected through 200125 temperature transducers.

    For Bently Nevada monitoring systems, signal integrity depends on correct sensor scaling and electrical validation. Therefore, installation procedures must maintain proper signal reference conditions and minimize interference from external wiring sources. The module supports isolated temperature inputs to reduce ground loop effects during distributed machinery monitoring applications.

    Frequently Asked Questions

    Q: What input devices are supported by the 200200-02-02-CN module?
    A: The module supports dual K-Type thermocouple inputs through 200125 temperature transducers. It processes two independent temperature measurement channels.

    Q: Does the ProTIM-R module provide electrical isolation for temperature inputs?
    A: Yes. The temperature input channels include electrical isolation to reduce ground loop interference between field devices and monitoring equipment.

    Q: What environmental limits apply to the thermocouple ProTIM-R variant?
    A: The operating temperature range is -25 deg C to +85 deg C, while storage temperature ranges from -40 deg C to +100 deg C.

    Field Installation Guidelines

    Install the 200200-02-02-CN module on a compatible DIN rail and verify mechanical engagement before connecting field wiring. Ensure thermocouple wiring follows correct polarity and maintains separation from high-voltage power conductors.

    Moreover, apply suitable contact protection methods, including DC4 grease on connector contacts where specified, to reduce corrosion risks in exposed environments. Use proper cable routing practices to limit electromagnetic interference and avoid parallel runs with high-current cables.

    Verify channel configuration before commissioning. Confirm thermocouple signal response, wiring continuity, and monitoring system communication status before placing the module into operational service.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!