{"product_id":"yokogawa-vi701-vnet-ip-interface-card","title":"Yokogawa VI701 | Vnet\/IP Interface Card","description":"\u003ch2\u003eYokogawa VI701 Vnet\/IP Interface Card\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed Vnet\/IP network communication in CENTUM VP and CENTUM CS 3000 platforms, the \u003cstrong\u003eYokogawa VI701\u003c\/strong\u003e (\u003cstrong\u003eVI701\u003c\/strong\u003e Vnet\/IP Interface Card) provides direct physical and electrical execution through a PCI-based Ethernet communication interface for HIS and engineering workstation integration.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single fixed model configuration only. No official suffix or option-code decomposition is specified within the available technical data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVI701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP Interface Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e1000 Mbps Full Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Requirement\u003c\/td\u003e\n\u003ctd\u003eCAT5e UTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCI Bus Specification\u003c\/td\u003e\n\u003ctd\u003ePCI Bus Specification Rev. 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Width\/Frequency\u003c\/td\u003e\n\u003ctd\u003e32-bit \/ 33 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from PCI bus supply load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e106.68 mm x 167.64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Communication Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe VI701 communication architecture operates through deterministic Ethernet transport within Yokogawa Vnet\/IP process control environments. The module supports 1000BASE-T transmission over CAT5e infrastructure using full-duplex communication paths between the workstation PCI subsystem and Layer 2 switching hardware.\u003c\/p\u003e\n\u003cp\u003eChannel communication status is indicated through dedicated hardware LEDs. The RDY indicator confirms successful onboard diagnostic completion, while RCV and SND indicators reflect active packet receive and transmit conditions on the control communication bus.\u003c\/p\u003e\n\u003cp\u003eThe PCI interface supports mixed 3.3 V and 5 V signaling environments compliant with PCI Revision 3.0 backplane specifications. Installation into PCI-X mechanical slots is possible when electrical compatibility is maintained at 33 MHz operating frequency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the VI701 support hot-swapping during system operation?\u003c\/strong\u003e\u003cbr\u003eA: The supplied specifications define the module as a PCI bus interface card. Standard PCI hardware installation practice requires complete host workstation power shutdown before insertion or removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cabling limitations apply to the Ethernet connection?\u003c\/strong\u003e\u003cbr\u003eA: The interface supports CAT5e UTP cabling with a maximum point-to-point distance of 100 m between the VI701 interface and the connected Layer 2 switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic functions are available directly on the hardware?\u003c\/strong\u003e\u003cbr\u003eA: The module includes RDY, RCV, and SND LED indicators for onboard diagnostic confirmation and communication activity monitoring during network operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eBefore installation, verify PCI slot voltage compatibility with 3.3 V \/ 5 V signaling requirements defined by the card specification. Confirm that the workstation chassis provides adequate airflow around adjacent PCI devices to avoid localized thermal accumulation.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet cabling separately from high-current AC power conductors and variable frequency drive output wiring to minimize induced electromagnetic interference on the Vnet\/IP communication path.\u003c\/p\u003e\n\u003cp\u003eUse properly terminated CAT5e cabling with maintained twist integrity up to the RJ45 termination point. Excessive cable untwist near the connector can increase susceptibility to packet transmission errors in industrial electrical environments.\u003c\/p\u003e\n\u003cp\u003eConfirm Layer 2 switch configuration supports 1000BASE-T full-duplex operation before commissioning the communication link.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44152728977496,"sku":"VI701","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/VI701-3.jpg?v=1780016838","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-vi701-vnet-ip-interface-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}