{"product_id":"yokogawa-temperature-monitoring-module-f3cx04-0n","title":"Yokogawa Temperature Monitoring Module | F3CX04-0N","description":"\u003ch2\u003eYokogawa F3CX04-0N Temperature Monitoring Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CX04-0N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3CX04\u003c\/strong\u003e Temperature Monitoring Module, operates as a dedicated hardware component for multi-channel temperature input processing within FA-M3 automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eYokogawa  F3CX04-0N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 W × 100 H × 106.1 D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eMax allowable ambient temperature change rate: 10 degC\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e440 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumberOfChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputIsolation\u003c\/td\u003e\n\u003ctd\u003eIsolated via photocouplers and transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminalVoltageWithstand\u003c\/td\u003e\n\u003ctd\u003e150 VAC tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmTypes\u003c\/td\u003e\n\u003ctd\u003eInput upper limit alarm, input lower limit alarm (with or without delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumberOfAlarmOutputs\u003c\/td\u003e\n\u003ctd\u003e4 points per channel (only alarms 1 and 2 have relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmDelayTimer\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarmUpTime\u003c\/td\u003e\n\u003ctd\u003e30 minutes min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMountingPosition\u003c\/td\u003e\n\u003ctd\u003eHorizontal only; inverted orientation not allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternalConnection\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block with M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputProcessingModes\u003c\/td\u003e\n\u003ctd\u003eSingle-input (default), Two-input changeover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOmron modules integrate deterministic backplane bus communication for FA-M3 systems. Firmware flash compatibility allows in-field updates without disrupting ongoing input monitoring. Channel-to-channel isolation is maintained to prevent cross-interference, supporting precise analog signal acquisition across all four inputs. Single- and two-input changeover modes allow paired or independent channel monitoring, with configurable alarm delay timers to align with system response requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Can the F3CX04-0N be hot-swapped while the FA-M3 base module is powered?\u003cbr\u003eA: No. The module requires system power-down before insertion or removal to prevent signal disruption and relay misoperation.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum rate of ambient temperature change the module can tolerate?\u003cbr\u003eA: The module supports up to 10 degC per hour. Faster changes may affect input accuracy and alarm triggering.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware updates compatible with all installed channel configurations?\u003cbr\u003eA: Yes, firmware flash operations preserve current input processing settings, but it is recommended to verify alarm and relay settings post-update.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module horizontally on the FA-M3 base; inverted or vertical mounting is not permitted.\u003c\/li\u003e\n\u003cli\u003eEnsure 18-point terminal block connections are tightened with M3.5 screws to maintain proper electrical isolation.\u003c\/li\u003e\n\u003cli\u003eRoute analog input wiring separately from high-current or switching circuits to minimize cross-talk.\u003c\/li\u003e\n\u003cli\u003eVerify ambient temperature stability; avoid locations with rapid thermal fluctuations exceeding 10 degC per hour.\u003c\/li\u003e\n\u003cli\u003eGround module shielding appropriately to reduce electromagnetic interference and maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44162913828952,"sku":"F3CX04-0N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3CX04-0N.jpg?v=1780276699","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-temperature-monitoring-module-f3cx04-0n","provider":"IndustriaX Limited","version":"1.0","type":"link"}