{"product_id":"yokogawa-f3xd16-3f-dc-input-module","title":"Yokogawa F3XD16-3F | DC Input Module","description":"\u003ch2\u003eYokogawa F3XD16-3F DC Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for receiving discrete DC field signals in FA-M3 controller systems, the \u003cstrong\u003eYokogawa F3XD16-3F\u003c\/strong\u003e (\u003cstrong\u003eF3XD16\u003c\/strong\u003e DC Input Module) provides direct physical\/electrical execution of 24 V DC digital input acquisition from switches, sensors, and relay contacts through 16 input channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.1654%; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 65.5012%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eModelBrand\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eYokogawa F3XD16-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eApprox. 175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eStandard FA-M3 module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e65 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eProductType\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eDC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eNumberOfInputs\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eInputType\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eDC voltage (Sink\/Source compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eRatedInputVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eOperatingVoltageRange\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e20.4 V DC to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eRatedInputCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e4.1 mA per point at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eInputImpedance\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eApprox. 5.6 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eIsolationMethod\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eCommonConfiguration\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003e16 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eInputResponseOFFtoON\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eSelectable from 62.5 us to 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eInputResponseONtoOFF\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eSelectable from 62.5 us to 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 39.1875px;\"\u003eExternalConnection\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 39.1875px;\"\u003e18-point detachable terminal block with M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.1654%; height: 19.5938px;\"\u003eStatusIndication\u003c\/td\u003e\n\u003ctd style=\"width: 65.5012%; height: 19.5938px;\"\u003eIndividual channel LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Signal Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe F3XD16-3F employs photocoupler isolation between external field circuits and the internal FA-M3 logic circuitry. Optical isolation prevents direct electrical continuity between field wiring and controller electronics while reducing susceptibility to conducted electrical noise from external devices and cable runs.\u003c\/p\u003e\n\u003cp\u003eThe module supports both sink and source wiring configurations, allowing integration with different sensor output types without requiring separate input card variants. Input state transitions are processed using selectable filtering periods ranging from 62.5 us to 16 ms for matching field signal characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the F3XD16-3F support both sink and source input devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module is designed for DC voltage inputs and supports both sink and source wiring configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What isolation technology is implemented on the input channels?\u003c\/strong\u003e\u003cbr\u003eA: The module uses photocoupler isolation between external input circuits and the PLC internal logic circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the input response time be adjusted for fast sensor signals?\u003c\/strong\u003e\u003cbr\u003eA: Yes. OFF-to-ON and ON-to-OFF response times are configurable from 62.5 us to 16 ms, allowing filtering selection according to application requirements.\u003c\/p\u003e\n\u003ch3\u003eFieldInstallationGuidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify field supply voltage remains within the specified 20.4 V DC to 26.4 V DC operating range before commissioning.\u003c\/li\u003e\n\u003cli\u003eRoute input signal cables separately from motor power conductors, contactor wiring, and variable-frequency drive output cables.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring on the designated detachable terminal block and verify terminal screw tightness according to site wiring standards.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to plant grounding practices and avoid multiple shield grounding points unless required by site standards.\u003c\/li\u003e\n\u003cli\u003eConfirm channel LED indications during startup to verify correct field device operation and input assignment.\u003c\/li\u003e\n\u003cli\u003eDe-energize the controller rack before module installation or removal unless the platform documentation explicitly permits energized replacement procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44163018260568,"sku":"F3XD16-3F","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3XD16-3F-3.jpg?v=1780279118","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-f3xd16-3f-dc-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}