{"product_id":"yokogawa-f3xc08-0c-no-voltage-contact-input-module","title":"Yokogawa F3XC08-0C | No-voltage Contact Input Module","description":"\u003ch2\u003eYokogawa F3XC08-0C No-voltage Contact Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3XC08-0C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3XC08-0C\u003c\/strong\u003e No-voltage Contact Input Module, operates as a dedicated hardware component for detecting and interfacing ON\/OFF dry-contact signals within FA-M3 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3XC08-0C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact module, standard FA-M3 form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e75 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputType\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact (dry contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumberOfInputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolationMethod\u003c\/td\u003e\n\u003ctd\u003eTransformer isolation per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputRatings\u003c\/td\u003e\n\u003ctd\u003e5 V DC min., 20 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eONResistance\u003c\/td\u003e\n\u003ctd\u003eMax 200 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFFResistance\u003c\/td\u003e\n\u003ctd\u003eMin 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaxSimultaneousInputs\u003c\/td\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputResponse\u003c\/td\u003e\n\u003ctd\u003eSampling time selectable: 0 μs, 62.5 μs, 250 μs, 1 ms, 16 ms (response = sampling period + 1 ms max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e10-point terminal block, M3.5 screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003eSeparate commons per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt\u003c\/td\u003e\n\u003ctd\u003eSupported per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Module Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e Each input has a dedicated common line, preventing electrical cross-talk and maintaining signal integrity in noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Integration:\u003c\/strong\u003e Compatible with 4-20 mA HART loop protocol systems for direct process monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e Maintains stable detection thresholds across ambient temperature variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal LED Indicators:\u003c\/strong\u003e Provides instantaneous visual verification of ON\/OFF input states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the F3XC08-0C handle external voltage on the input terminals?\u003cbr\u003eA: No, the inputs are designed for dry contacts only. Applying external voltage may damage the module.\u003c\/p\u003e\n\u003cp\u003eQ: What is the input response time range?\u003cbr\u003eA: The input sampling time is selectable from 0 μs, 62.5 μs, 250 μs, 1 ms, to 16 ms. The effective response time is the sampling period plus 1 ms maximum.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for this module?\u003cbr\u003eA: No, the module does not support hot-swap operation. Power must be removed from the rack prior to installation or removal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure separate commons are properly wired for each channel to maintain isolation.\u003c\/li\u003e\n\u003cli\u003eRoute field signal wiring away from high-voltage AC or noisy switching lines to minimize interference.\u003c\/li\u003e\n\u003cli\u003eUse recommended copper wire cross-section (0.33–0.82 mm²) and tighten M3.5 screws to 0.8 N·m.\u003c\/li\u003e\n\u003cli\u003eVerify LED status indicators after wiring before applying power to the system.\u003c\/li\u003e\n\u003cli\u003eMaintain transformer isolation distance and avoid bridging terminals between channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44163012558936,"sku":"F3XC08-0C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3XC08-0C.jpg?v=1780278281","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-f3xc08-0c-no-voltage-contact-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}