{"product_id":"yokogawa-anb10d-420-cu2t-ndel-esb-bus-node-unit","title":"Yokogawa ANB10D-420\/CU2T\/NDEL ESB Bus Node Unit","description":"\u003ch2\u003eYokogawa ANB10D-420\/CU2T\/NDEL ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed backplane communication in Yokogawa CENTUM VP DCS networks, the \u003cstrong\u003eYokogawa ANB10D-420\/CU2T\/NDEL\u003c\/strong\u003e (\u003cstrong\u003eANB10D\u003c\/strong\u003e ESB Bus Node Unit) provides direct physical layer interfacing between Field Control Units and FIO modules. The unit executes deterministic data transfer over dual-redundant Enhanced System Bus architecture while managing distributed I\/O power distribution and bus termination functions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Element\u003c\/th\u003e\n\u003cth\u003eDefinition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type (No explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Unit with integrated ESB Bus terminators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware license for Node Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-420\/CU2T\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg (Fully loaded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e483 mm x 221 mm x 214 mm (19-inch rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 VA \/ 5.5 A @ 220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount (M5 x 4 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFoundation Fieldbus H1 Segment Coupling\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D interfaces with field devices utilizing Foundation Fieldbus H1 protocols through compatible FIO modules. The unit supports channel-to-channel isolation barriers to suppress ground loop currents. When configured with the \/CU2T option, the integrated termination resistors maintain 100 ohm characteristic impedance matching for the ESB bus physical layer, ensuring deterministic macrocycle execution without signal reflection artifacts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \/NDEL software license permit hot-swapping of I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \/NDEL license governs node expansion capacity within the DCS architecture. Physical hot-swap capability is determined by the specific FIO module installed; standard analog input modules do not support live removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum permissible voltage fluctuation for the 220-240 V AC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The power supply accepts a permissible input range of 187 to 264 V AC. Operation outside this range triggers an internal fault status on the ESB bus diagnostic registers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \/CU2T terminator required if the node is mid-bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \/CU2T connector unit is mechanically required for installation, but the internal termination resistors are only jumper-activated for the final node in the daisy-chain topology.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSecure the unit to the 19-inch rack using four M5 screws. Ensure the rack frame is bonded to the plant functional ground grid with a conductor of less than 100 ohm resistance. When installing the \/CU2T connector, verify that the ESB bus cable shield is terminated with 360-degree circumferential contact at the connector hood to prevent EMI ingress. For dual-redundant configurations, both power supply modules must be energized simultaneously to achieve the specified 200 VA load capacity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44187246264408,"sku":"ANB10D-420\/CU2T\/NDEL","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-420CU2TNDEL.jpg?v=1780631671","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-anb10d-420-cu2t-ndel-esb-bus-node-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}