{"product_id":"yokogawa-aip827-1-vnet-ip-interface-card-for-centum-vp","title":"Yokogawa AIP827-1 Vnet\/IP Interface Card for CENTUM VP","description":"\u003ch3\u003e\u003cspan\u003eProduct Overview:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eYokogawa AIP827-1\u003c\/span\u003e is a high-performance \u003cspan\u003eVnet\/IP Interface Card\u003c\/span\u003e used in \u003cspan\u003eHuman Interface Stations (HIS)\u003c\/span\u003e and \u003cspan\u003eEngineering Stations (ENG)\u003c\/span\u003e within \u003cspan\u003eYokogawa’s CENTUM VP\u003c\/span\u003e and \u003cspan\u003eCENTUM CS 3000 Distributed Control System (DCS)\u003c\/span\u003e environments. Unlike traditional I\/O modules, the AIP827-1 is a \u003cspan\u003ePCI Express (PCIe)\u003c\/span\u003e card that installs directly into a \u003cspan\u003ePC or server\u003c\/span\u003e, enabling communication with \u003cspan\u003eYokogawa’s proprietary Vnet\/IP network\u003c\/span\u003e for real-time control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual-Redundant Ports:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEquipped with two \u003cspan\u003eRJ45 Ethernet ports\u003c\/span\u003e to connect to \u003cspan\u003e\"Bus 1\"\u003c\/span\u003e and \u003cspan\u003e\"Bus 2\"\u003c\/span\u003e of the redundant \u003cspan\u003eVnet\/IP\u003c\/span\u003e network, ensuring \u003cspan\u003ehigh availability\u003c\/span\u003e and \u003cspan\u003ereliability\u003c\/span\u003e for mission-critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCI Express Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe card uses a \u003cspan\u003ePCIe x1 slot\u003c\/span\u003e, making it compatible with modern \u003cspan\u003eindustrial PCs\u003c\/span\u003e and \u003cspan\u003eworkstations\u003c\/span\u003e (e.g., \u003cspan\u003eDell\u003c\/span\u003e or \u003cspan\u003eHP\u003c\/span\u003e), offering \u003cspan\u003efast data transfer\u003c\/span\u003e capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Speed Communication:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWith \u003cspan\u003e1 Gbps network speed\u003c\/span\u003e, the AIP827-1 guarantees that \u003cspan\u003eprocess data\u003c\/span\u003e, \u003cspan\u003ealarms\u003c\/span\u003e, and \u003cspan\u003econtrol commands\u003c\/span\u003e are transmitted with the \u003cspan\u003edeterminism\u003c\/span\u003e required for industrial safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTime Synchronization:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports \u003cspan\u003ehigh-precision time synchronization\u003c\/span\u003e across the DCS network, ensuring \u003cspan\u003eaccurate event logs\u003c\/span\u003e to the millisecond, essential for system diagnostics and troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOffloading Processor:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe onboard \u003cspan\u003eprocessor\u003c\/span\u003e handles \u003cspan\u003enetwork protocol stacks\u003c\/span\u003e, freeing the PC’s main CPU from managing network traffic and ensuring smoother operations during high-traffic periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAIP827-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express (PCIe) x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps (1000Base-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (Shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Yokogawa Proprietary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Stations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 64 stations per domain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 5.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported OS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows 10 \/ Server 2016\/2019\/2022 (Revision-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eApplication \u0026amp; Functionality:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eAIP827-1\u003c\/span\u003e is essential in a \u003cspan\u003eVnet\/IP\u003c\/span\u003e setup, allowing the \u003cspan\u003eHuman Interface Station (HIS)\u003c\/span\u003e or \u003cspan\u003eEngineering Station (ENG)\u003c\/span\u003e to interface with \u003cspan\u003eField Control Stations (FCS)\u003c\/span\u003e and other nodes. This ensures \u003cspan\u003etimely\u003c\/span\u003e and \u003cspan\u003ereliable data transmission\u003c\/span\u003e for critical process control, \u003cspan\u003ealarm monitoring\u003c\/span\u003e, and \u003cspan\u003econtrol operations\u003c\/span\u003e.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43947061641304,"sku":"AIP827-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AIP827-1_ef7b2df3-b7d1-455f-bc62-9dacf7d5e611.jpg?v=1775116716","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aip827-1-vnet-ip-interface-card-for-centum-vp","provider":"IndustriaX Limited","version":"1.0","type":"link"}