{"product_id":"yokogawa-aip602-vnet-coupler-unit-for-centum-vp-cs-3000","title":"Yokogawa AIP602 Vnet Coupler Unit for CENTUM VP \u0026 CS 3000","description":"\u003ch3\u003e\u003cspan\u003eProduct Overview:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eYokogawa AIP602\u003c\/span\u003e is a high-performance \u003cspan\u003eVnet Coupler Unit\u003c\/span\u003e, also known as a \u003cspan\u003eVnet\/IP to Vnet Gateway\u003c\/span\u003e, used within the \u003cspan\u003eCENTUM VP\u003c\/span\u003e and \u003cspan\u003eCENTUM CS 3000\u003c\/span\u003e systems. Unlike \u003cspan\u003ePC cards\u003c\/span\u003e like the \u003cspan\u003eAIP827\u003c\/span\u003e, the \u003cspan\u003eAIP602\u003c\/span\u003e is a standalone, \u003cspan\u003erack-mounted hardware device\u003c\/span\u003e designed to facilitate communication between different \u003cspan\u003econtrol network segments\u003c\/span\u003e or \u003cspan\u003edomains\u003c\/span\u003e. It is a crucial component for ensuring \u003cspan\u003ehigh-reliability communication\u003c\/span\u003e over large distances or complex network topologies.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual Redundancy:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFully supports \u003cspan\u003eYokogawa’s redundant network architecture\u003c\/span\u003e (Bus 1 and Bus 2), ensuring \u003cspan\u003ereliable and fault-tolerant communication\u003c\/span\u003e between network segments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGalvanic Isolation:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides \u003cspan\u003eelectrical isolation\u003c\/span\u003e between different segments of the network to protect against \u003cspan\u003eground loops\u003c\/span\u003e and \u003cspan\u003eelectromagnetic interference (EMI)\u003c\/span\u003e, ensuring clean and stable signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal Conditioning:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRegenerates and \u003cspan\u003econditions the digital signal\u003c\/span\u003e, maintaining \u003cspan\u003eclean waveforms\u003c\/span\u003e and preventing \u003cspan\u003edata corruption\u003c\/span\u003e over long-distance cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-Swappable:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for \u003cspan\u003eindustrial availability\u003c\/span\u003e, this feature allows for \u003cspan\u003emaintenance\u003c\/span\u003e or replacement without interrupting the operation of the entire control network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Connectivity:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both \u003cspan\u003eVnet (coaxial)\u003c\/span\u003e and \u003cspan\u003eVnet\/IP (RJ45\/fiber)\u003c\/span\u003e, making it adaptable for various configurations and network needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAIP602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP or Vnet Coupler \/ Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack-mount or Baseplate-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eVnet (Coaxial) \/ Vnet\/IP (RJ45\/Fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC or 220-240 VAC (Model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Use Cases:\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDomain Coupling:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUsed to connect a \u003cspan\u003eDomain 1\u003c\/span\u003e control network to a \u003cspan\u003eDomain 2\u003c\/span\u003e network, ensuring logical separation of traffic while allowing communication between different control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistance Extension:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eActs as a \u003cspan\u003esignal repeater\u003c\/span\u003e, extending the physical distance between \u003cspan\u003eField Control Stations (FCS)\u003c\/span\u003e when it exceeds the typical cable limitations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMedia Conversion:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFacilitates \u003cspan\u003emedia conversion\u003c\/span\u003e from \u003cspan\u003ecoaxial Vnet\u003c\/span\u003e to \u003cspan\u003efiber-optic\u003c\/span\u003e or \u003cspan\u003eEthernet-based Vnet\/IP\u003c\/span\u003e in certain configurations, allowing for flexible network setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cspan\u003eTroubleshooting \u0026amp; Maintenance:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStatus Indicators:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSTATUS (Green):\u003c\/span\u003e Normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eERROR (Red):\u003c\/span\u003e Indicates an internal hardware failure or \u003cspan\u003econfiguration mismatch\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRCV\/SND (Orange):\u003c\/span\u003e Indicates data traffic activity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCable Integrity:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSince the AIP602 often serves as the \u003cspan\u003emid-point\u003c\/span\u003e in a network, failure of this unit can disrupt communication for an entire segment of the plant. \u003cspan\u003eEnsure BNC connectors\u003c\/span\u003e for \u003cspan\u003eVnet\u003c\/span\u003e are properly connected and terminated with \u003cspan\u003e50Ω resistors\u003c\/span\u003e, especially if the unit is at the end of a line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental Check:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe unit may be placed in \u003cspan\u003esatellite rack rooms\u003c\/span\u003e, making it susceptible to \u003cspan\u003edust buildup\u003c\/span\u003e. Regularly check that \u003cspan\u003ecooling vents\u003c\/span\u003e are clear to prevent overheating and \u003cspan\u003ethermal shutdowns\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHardware Notes:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIf you are \u003cspan\u003emigrating a legacy CENTUM CS\u003c\/span\u003e system to \u003cspan\u003eCENTUM VP\u003c\/span\u003e, the \u003cspan\u003eAIP602\u003c\/span\u003e often serves as the critical bridge that facilitates communication between \u003cspan\u003enew VP stations\u003c\/span\u003e and \u003cspan\u003eolder CS control stations\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43947119181912,"sku":"AIP602","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AIP602_03291186-89c3-4f0d-9a7b-3fad56a6129a.jpg?v=1775116898","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aip602-vnet-coupler-unit-for-centum-vp-cs-3000","provider":"IndustriaX Limited","version":"1.0","type":"link"}