{"product_id":"yokogawa-aip512-s2-communication-module-v-net-esb-rio","title":"Yokogawa AIP512-S2 Communication Module V-Net ESB RIO","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP512-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication interface module is engineered for seamless data exchange within CENTUM VP and CENTUM CS 3000 distributed control systems. It operates as a multifunctional interface, supporting V-Net communication, ESB backplane connectivity, and Remote I\/O (RIO) integration.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-reliability industrial environments, this module enables stable, bidirectional communication between controllers, PLCs, and distributed I\/O systems. Its flexible configuration allows it to function across multiple network layers, making it suitable for both system expansion and legacy integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-role communication module supporting V-Net, ESB, and RIO architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeterministic data transmission for control-critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed ESB backplane communication for I\/O data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade construction for long-term stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated LED indicators for real-time diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure terminal connections for vibration-resistant installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAIP512-S2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface \/ Bus Coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eV-Net, ESB (Extended Serial Backplane), RIO Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eController ↔ PLC ↔ Remote I\/O data exchange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV-Net Speed\u003c\/td\u003e\n\u003ctd\u003e125 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Backplane Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIO Communication\u003c\/td\u003e\n\u003ctd\u003eTwisted-pair bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax ESB Distance\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (via system backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 10–15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4–0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eRack or DIN rail (variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHardware switch settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (M4, ESB variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDue to multiple hardware configurations within the AIP512 series, dimensions vary:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact V-Net version: approx. 152 × 76 × 254 mm, lightweight design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRIO interface version: approx. 225 × 140 × 92 mm, heavier industrial housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis variation reflects different installation roles within the control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandard: 0°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended (RIO variant): –20°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5% to 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance: CE, industrial EMC and safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control systems (DCS) integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC and controller network communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O system expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess industries such as oil \u0026amp; gas, power generation, and chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What roles can the AIP512-S2 module perform?\u003c\/strong\u003e\u003cbr\u003eA: It can function as a V-Net coupler, ESB bus interface, or RIO communication module depending on system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module suitable for long-distance communication?\u003c\/strong\u003e\u003cbr\u003eA: It is optimized for high-speed, short-distance ESB communication (up to 10 m) and reliable field-level RIO connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the module powered?\u003c\/strong\u003e\u003cbr\u003eA: It receives 24 V DC power directly from the system backplane, eliminating the need for external supply wiring.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43947050762328,"sku":"AIP512-S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AIP512_S2_a7cff300-f9da-45c1-b663-3b8e80de9d25.jpg?v=1775116657","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aip512-s2-communication-module-v-net-esb-rio","provider":"IndustriaX Limited","version":"1.0","type":"link"}