{"product_id":"yokogawa-aip121-s2-16-channel-analog-input-module-centum-vp-cs-3000","title":"Yokogawa AIP121-S2 | 16-Channel Analog Input Module | CENTUM VP\/CS 3000","description":"\u003ch3\u003eShopify Product Title:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYokogawa AIP121-S2 | Analog Input Module | CENTUM VP\/CS 3000 | 16 Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Description:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eYokogawa AIP121-S2\u003c\/span\u003e is a high-performance analog input module designed to work seamlessly within the Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module plays a crucial role in the system’s FIO (Field Input\/Output) architecture, specifically engineered for industrial environments where reliable and precise signal acquisition is essential. It is optimized for interfacing with 2-wire or 4-wire transmitters, ensuring accurate measurement and isolation of field data.\u003c\/p\u003e\n\u003cp\u003eWith \u003cspan\u003e16 isolated input channels\u003c\/span\u003e, the \u003cspan\u003eAIP121-S2\u003c\/span\u003e can handle a range of input signals, including the widely-used 4-20 mA DC current loop. The module offers high-density signal conditioning, ensuring that field signals are converted and isolated efficiently before being sent to the system’s control units.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e16 Isolated Analog Input Channels\u003c\/span\u003e for reliable data acquisition in challenging industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e input signal compatibility, supporting standard current loop signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eImpedance\u003c\/span\u003e: 250 Ω (Typical) for optimal signal conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e: ±0.1% of full span, ensuring precise measurement of field signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh Isolation\u003c\/span\u003e: 1500 V AC isolation between field devices and system, protecting your system from electrical disturbances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUpdate Time\u003c\/span\u003e: 10 ms per 16 channels, enabling fast data processing and response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow Power Consumption\u003c\/span\u003e: Max. 450 mA (5 V DC from backplane) for energy-efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting Compatibility\u003c\/span\u003e: Designed for installation in \u003cspan\u003eANB10\u003c\/span\u003e, \u003cspan\u003eANB11\u003c\/span\u003e, or \u003cspan\u003eANT10\u003c\/span\u003e units for easy integration into existing setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis module is ideal for applications where high-accuracy and reliable signal acquisition are paramount, such as temperature monitoring, pressure measurements, or flow control in industrial automation systems.\u003c\/p\u003e\n\u003ch4\u003eApplications:\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature, Pressure, and Flow Measurement\u003c\/span\u003e: Suitable for use in industrial control systems where continuous, accurate data is crucial.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess Control\u003c\/span\u003e: Essential in maintaining optimal conditions for sensitive manufacturing processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ:\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the AIP121-S2 handle both 2-wire and 4-wire transmitters?\u003c\/span\u003e\u003cbr\u003eA: Yes, the AIP121-S2 is designed to interface with both 2-wire and 4-wire transmitters for maximum flexibility in signal acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the maximum isolation voltage?\u003c\/span\u003e\u003cbr\u003eA: The AIP121-S2 offers 1500 V AC isolation between field devices and the system, ensuring protection against electrical surges and noise.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How many channels does the module support?\u003c\/span\u003e\u003cbr\u003eA: The \u003cspan\u003eAIP121-S2\u003c\/span\u003e supports up to \u003cspan\u003e16 isolated analog input channels\u003c\/span\u003e, making it ideal for applications with multiple sensors.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43948023087192,"sku":"AIP121-S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AIP121S2_d582115f-35ec-43e4-a6ea-5b4e34d9a7c8.jpg?v=1775118754","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aip121-s2-16-channel-analog-input-module-centum-vp-cs-3000","provider":"IndustriaX Limited","version":"1.0","type":"link"}