{"product_id":"yokogawa-adv561-p50-digital-output-module-64-channel","title":"Yokogawa ADV561-P50 Digital Output Module-64-channel","description":"\u003ch2\u003eYokogawa ADV561-P50 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated 24 VDC discrete signal execution in CENTUM and related Yokogawa control architectures, the \u003cstrong\u003eYokogawa ADV561-P50\u003c\/strong\u003e (\u003cstrong\u003eADV561\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module supports 64-channel digital output handling with pulse width output and time-proportional output functionality integrated into the output control structure.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix Code\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output function and time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV561-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eDigital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Output\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime-Proportional Output\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSystem rack\/backplane installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ADV561-P50 implements isolated digital output channel architecture for separation of field-side switching circuits from the control backplane interface. Isolation design reduces transient propagation between adjacent output circuits during inductive load switching and minimizes common return interference within multi-channel discrete output assemblies.\u003c\/p\u003e\n\u003cp\u003eThe integrated pulse width output function supports duty-cycle based discrete actuation, while the time-proportional output mode permits direct modulation of externally connected solenoids, relays, and proportional control elements operating on 24 VDC field power distribution networks.\u003c\/p\u003e\n\u003cp\u003eOutput routing is handled through Yokogawa DCS I\/O carrier structures with controlled backplane communication timing between processor and field output stages.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV561-P50 support hot swapping during operation?\u003c\/strong\u003e\u003cbr\u003eA: Module replacement capability depends on the installed Yokogawa control station architecture and active controller redundancy configuration. Field output state behavior during insertion\/removal must be validated against the applicable system manual before live replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field loads can be connected to the digital outputs?\u003c\/strong\u003e\u003cbr\u003eA: The module is intended for 24 VDC discrete field devices such as interposing relays, solenoid valves, annunciators, and discrete actuator interfaces compatible with the module output rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are output channels electrically isolated from each other?\u003c\/strong\u003e\u003cbr\u003eA: The module is specified as an isolated digital output module. Isolation is implemented to reduce electrical interference transfer between field-side output circuits and internal system electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify external field voltage polarity before energizing output terminals.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from analog signal cabling to reduce switching noise coupling.\u003c\/li\u003e\n\u003cli\u003eUse shield grounding at a single designated grounding point within the control cabinet.\u003c\/li\u003e\n\u003cli\u003eConfirm inductive suppression devices are installed across relay coils and solenoid loads where applicable.\u003c\/li\u003e\n\u003cli\u003eMaintain terminal tightening torque according to Yokogawa cabinet installation procedures.\u003c\/li\u003e\n\u003cli\u003eConfirm backplane connector alignment before module insertion into the I\/O rack assembly.\u003c\/li\u003e\n\u003cli\u003ePerform loop verification of all output channels after commissioning or module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44146190843992,"sku":"ADV561-P50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV561-P50-3.jpg?v=1779847205","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-adv561-p50-digital-output-module-64-channel","provider":"IndustriaX Limited","version":"1.0","type":"link"}