{"product_id":"yokogawa-adv551-p50-d5a00-digital-output-modules","title":"Yokogawa ADV551-P50\/D5A00 Digital Output Modules","description":"\u003ch1\u003eYokogawa ADV551-P50\/D5A00 Digital Output Modules\u003c\/h1\u003e\n\u003cp\u003eConfigured for 32-channel discrete signal execution in CENTUM-compatible DCS architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV551-P50\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV551\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Modules) provides direct current sink output handling for field-side status and pulse transmission circuits. The module integrates pulse width output capability together with a KS Cable Interface Adapter for 32-channel digital interfacing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output function\/time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter for 32-channel Digital (ATD5A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms max (status output), 10 ms max (mixed status\/pulse output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute between output signal and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Structure\u003c\/td\u003e\n\u003ctd\u003eCommon minus (-) side every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption Adapter\u003c\/td\u003e\n\u003ctd\u003eATD5A-00 KS Cable Interface Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and DCS Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P50\/D5A00 module implements grouped common isolation architecture with separation applied every 16 channels on the common minus side. This arrangement reduces inter-channel interference during simultaneous status and pulse output operation within distributed control system signal paths.\u003c\/p\u003e\n\u003cp\u003eThe current sink output structure is intended for 24 V DC field-side switching circuits where external supply regulation remains within the specified 20.4 to 26.4 V DC operating window. Pulse width output handling supports both short-duration command pulses and extended time-proportional output cycles up to 7200 s.\u003c\/p\u003e\n\u003cp\u003eDielectric isolation ratings include 2 kV AC withstand capability between output signals and system circuitry, together with 500 V AC isolation between grouped commons for one minute test duration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV551-P50\/D5A00 support pulse-based output operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module includes pulse width output and time-proportional output functions with selectable pulse durations from 8 ms to 7200 s.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output topology is used by the module?\u003c\/strong\u003e\u003cbr\u003eA: The module uses a current sink output format intended for 24 V DC discrete field output circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are all 32 channels isolated individually?\u003c\/strong\u003e\u003cbr\u003eA: No. The common minus side is grouped in 16-channel sections with isolation applied between commons according to the specified 500 V AC withstand rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify external field supply voltage remains within the specified 20.4 to 26.4 V DC range before energizing output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate pulse output wiring from high-current motor or relay cabling to reduce inductive noise coupling into digital signal paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield grounding at a single designated control cabinet grounding point to prevent ground loop circulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm KS Cable Interface Adapter alignment and connector seating before applying field power to the module assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not route low-level signal cables in parallel with AC mains conductors inside shared cable trays without metallic segregation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143088304216,"sku":"ADV551-P50\/D5A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV551-P50D5A00.jpg?v=1779759607","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-adv551-p50-d5a00-digital-output-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}