{"product_id":"yokogawa-adv151-p13-digital-input-module-new-original-stock","title":"Yokogawa ADV151-P13 Digital Input Module | New \u0026 Original Stock","description":"\u003ch1\u003eYokogawa ADV151-P13 Digital Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for contact status signal acquisition in CENTUM and related Yokogawa DCS platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-P13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct physical and electrical execution for multi-channel discrete input processing and transistor contact signal interfacing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eModel Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P13\u003c\/td\u003e\n\u003ctd\u003eSpecific hardware and interface revision suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eContact input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Signal Level\u003c\/td\u003e\n\u003ctd\u003e100 kOhm or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Signal Level\u003c\/td\u003e\n\u003ctd\u003e200 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e16 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Input Function\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eControl unit installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and Discrete Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-P13 module implements channel isolation architecture for discrete contact signal processing inside distributed control system environments. Input transition recognition is executed through defined resistance thresholds, with OFF-state recognition at 100 kOhm or higher and ON-state recognition at 200 Ohm or lower.\u003c\/p\u003e\n\u003cp\u003eThe transistor contact output section operates independently from field contact detection circuitry to reduce electrical propagation between adjacent signal paths. Isolation structure supports stable status acquisition during simultaneous multi-channel switching events and minimizes channel-to-channel interference within cabinet-level wiring assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV151-P13 support hot swapping during system operation?\u003c\/strong\u003e\u003cbr\u003eA: The provided specification does not define online insertion or hot-swap capability. Module replacement procedures should follow the applicable Yokogawa control station maintenance manual and system shutdown requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field devices can be connected to the input channels?\u003c\/strong\u003e\u003cbr\u003eA: The module is intended for dry contact or contact status input signals meeting the specified ON and OFF resistance thresholds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is pushbutton pulse detection supported by the module firmware?\u003c\/strong\u003e\u003cbr\u003eA: No. The pushbutton input function is explicitly listed as not supported for the ADV151-P13.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module inside a grounded industrial control enclosure with separation maintained between discrete input wiring and high-voltage power conductors. Use shielded field wiring where cabinet electromagnetic interference is present.\u003c\/p\u003e\n\u003cp\u003eVerify contact resistance values from field devices before commissioning to ensure compliance with the defined ON and OFF threshold requirements. Terminal tightening torque should follow the associated Yokogawa hardware installation manual for the host control unit.\u003c\/p\u003e\n\u003cp\u003eDuring panel routing, avoid parallel cable placement with inverter output conductors or high-current motor feeders to reduce transient coupling into low-level status input circuits.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143083389016,"sku":"ADV151-P13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV151-P13-3.jpg?v=1779758913","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-adv151-p13-digital-input-module-new-original-stock","provider":"IndustriaX Limited","version":"1.0","type":"link"}