{"product_id":"yokogawa-adm52c-analog-recorder-3-channels","title":"Yokogawa ADM52C Analog Recorder | 3 channels","description":"\u003ch2\u003eYokogawa ADM52C S3 Analog Recorder\u003c\/h2\u003e\n\u003cp\u003eConfigured for continuous process signal recording in analog acquisition systems, the \u003cstrong\u003eYokogawa ADM52C S3\u003c\/strong\u003e (\u003cstrong\u003eADM52C S3\u003c\/strong\u003e Analog Recorder) provides direct physical\/electrical execution of multi-channel measurement logging across DC voltage, DC current, thermocouple, and RTD input interfaces.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADM52C\u003c\/strong\u003e: Base recorder series designation (as provided)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS3\u003c\/strong\u003e: Revision \/ configuration suffix (not further specified in provided technical data)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo additional factory-defined decoding information is available in the supplied dataset.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ADM52C S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e144 x 144 x 265 mm (panel cutout 138 x 138 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Method\u003c\/td\u003e\n\u003ctd\u003eDot line recording with dual pens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart Speed\u003c\/td\u003e\n\u003ctd\u003e10 to 100 mm\/h (6 selectable steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eDC voltage, DC current, thermocouple, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Input Conditioning (Yokogawa Process Recorder Architecture)\u003c\/h3\u003e\n\u003cp\u003eThe input architecture implements isolated measurement front-ends for each acquisition channel, supporting mixed-signal conditioning across voltage, current, and resistance temperature devices. Thermocouple and RTD inputs rely on internal compensation routines consistent with cold junction compensation (CJC) principles for stable reference junction handling. Signal routing is optimized for low drift analog amplification prior to mechanical chart recording via dual-pen dot line mechanism.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ADM52C S3 simultaneously process mixed input types across channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Each channel supports independent configuration for DC voltage, DC current, thermocouple, or RTD input types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the impact of chart speed selection on data resolution?\u003c\/strong\u003e\u003cbr\u003eA: Chart speed (10 to 100 mm\/h in 6 steps) directly affects temporal resolution of recorded traces; higher speed increases time-axis granularity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the device require external signal conditioning modules?\u003c\/strong\u003e\u003cbr\u003eA: No external conditioning is required for standard supported inputs; internal scaling and isolation are integrated at channel level.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount unit in a standard panel cutout of 138 x 138 mm with secure mechanical fixation to prevent vibration-induced chart distortion\u003c\/li\u003e\n\u003cli\u003eMaintain wiring separation between signal input lines and AC power supply (100 to 240 VAC) to reduce electromagnetic coupling\u003c\/li\u003e\n\u003cli\u003eEnsure thermocouple and RTD wiring uses appropriate compensation conductors and correct polarity alignment\u003c\/li\u003e\n\u003cli\u003eConfirm ambient operating conditions remain within 0 to 50 degC range for mechanical recorder stability\u003c\/li\u003e\n\u003cli\u003eProvide adequate rear clearance for ventilation and terminal access during maintenance operations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44150434988120,"sku":"ADM52C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADM52C.jpg?v=1779939834","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-adm52c-analog-recorder-3-channels","provider":"IndustriaX Limited","version":"1.0","type":"link"}