{"product_id":"yokogawa-aav144-s50-analog-input-module-for-centum-vp","title":"Yokogawa AAV144-S50 Analog Input Module for Centum VP","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAAV144-S50\u003c\/strong\u003e analog input module from Yokogawa is developed for reliable signal acquisition in distributed control and process automation environments. Designed for integration with the Centum VP control platform, this module supports stable monitoring of field instrumentation and process variables in continuous industrial operations.\u003c\/p\u003e\n\u003cp\u003eEngineered for high accuracy and electrical isolation, the module processes multiple analog signal formats commonly used in industrial plants. Its robust hardware architecture allows dependable operation in demanding environments such as petrochemical facilities, power generation plants, water treatment systems, and manufacturing lines.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports multiple industrial analog input formats\u003c\/li\u003e\n\u003cli\u003eHigh precision signal conversion with stable long-term operation\u003c\/li\u003e\n\u003cli\u003eElectrical isolation between channels and system circuits\u003c\/li\u003e\n\u003cli\u003eFast sampling response for real-time process monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for harsh industrial operating conditions\u003c\/li\u003e\n\u003cli\u003eCompatible with Yokogawa Centum VP distributed control systems\u003c\/li\u003e\n\u003cli\u003eDIN rail or rack-mounted system integration depending on cabinet configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eAAV144-S50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCentum VP DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSupported Input Signals\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4-20 mA, 0-10 V, Thermocouple, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e16 channels typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e+\/-0.1 percent full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSampling Speed\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eUp to 1000 samples per second per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e1500 VAC channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e-20 C to +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e5 to 95 percent RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eRack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eInternal DCS backplane connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eInput status and module self-diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAAV144-S50\u003c\/strong\u003e module is suitable for industrial automation systems requiring continuous analog signal monitoring and accurate process data acquisition.\u003c\/p\u003e\n\u003cp\u003eCommon applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas processing systems\u003c\/li\u003e\n\u003cli\u003eChemical production plants\u003c\/li\u003e\n\u003cli\u003eThermal and renewable power facilities\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli\u003ePharmaceutical process control\u003c\/li\u003e\n\u003cli\u003eFactory automation and instrumentation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides stable analog signal handling with high noise immunity and channel isolation. This helps reduce signal interference in complex control cabinets and improves measurement consistency across process loops.\u003c\/p\u003e\n\u003cp\u003eIts compatibility with thermocouples and RTD sensors also enables direct temperature monitoring without requiring additional signal converters in many installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat control system is compatible with the AAV144-S50 module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for Yokogawa Centum VP distributed control systems and related compatible DCS architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module support temperature sensor inputs?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The module supports thermocouple and RTD input signals in addition to standard current and voltage signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the module operate in high-temperature industrial environments?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The operating temperature range supports industrial installations from -20 C to +60 C.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs channel isolation included?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003eYes. The module provides 1500 VAC isolation between channels and the system to improve operational safety and signal reliability.\u003cstrong\u003eShopify Product Title.\u003c\/strong\u003e\n\u003c\/h3\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44139567644760,"sku":"AAV144-S50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AAV144-S50.jpg?v=1779671374","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aav144-s50-analog-input-module-for-centum-vp","provider":"IndustriaX Limited","version":"1.0","type":"link"}