{"product_id":"yokogawa-aav144-s00-analog-input-module-centum-dcs","title":"Yokogawa AAV144-S00 Analog Input Module Centum DCS","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAAV144-S00\u003c\/strong\u003e analog input module is a Yokogawa signal acquisition unit designed for distributed control system applications requiring stable and accurate analog data processing. The module is widely deployed in process automation environments where multiple field devices must be monitored continuously with high electrical isolation and fast response times.\u003c\/p\u003e\n\u003cp\u003eSupporting several industrial voltage input ranges, the module integrates directly into Yokogawa DCS architectures and provides dependable measurement performance for process instrumentation, monitoring systems, and plant control networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 isolated analog input channels\u003c\/li\u003e\n\u003cli\u003eCompatible with Yokogawa distributed control systems\u003c\/li\u003e\n\u003cli\u003eSupports multiple voltage signal ranges\u003c\/li\u003e\n\u003cli\u003eHigh-speed signal refresh for real-time monitoring\u003c\/li\u003e\n\u003cli\u003eElectrical isolation for improved system protection\u003c\/li\u003e\n\u003cli\u003eStable analog conversion with low temperature drift\u003c\/li\u003e\n\u003cli\u003eCompact lightweight module structure for cabinet integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eAAV144-S00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSystem Platform\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eYokogawa Centum DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSupported Input Ranges\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1 to 5 V, -10 to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eSignal Configuration\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSelectable input configuration for channels 1 to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e+\/-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eIsolation Strength\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1500 VAC for 1 minute between input and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eInput Resistance Power ON\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e1 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eInput Resistance Power OFF\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e200 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eTypical Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e+\/-4 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eMaximum Accuracy Error\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e+\/-20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eData Update Interval\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eTemperature Drift Typical\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e+\/-4 mV per 10 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eTemperature Drift Maximum\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e+\/-20 mV per 10 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eMax 500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eModule Weight\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003eApprox. 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eRack-mounted DCS module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003eInternal module monitoring and signal diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAAV144-S00\u003c\/strong\u003e module is commonly used in industrial facilities that require continuous analog signal monitoring and integration with process control systems.\u003c\/p\u003e\n\u003cp\u003eTypical industries include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePetrochemical processing\u003c\/li\u003e\n\u003cli\u003ePower generation\u003c\/li\u003e\n\u003cli\u003eWater treatment facilities\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing\u003c\/li\u003e\n\u003cli\u003ePulp and paper production\u003c\/li\u003e\n\u003cli\u003eFactory process automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module is designed for environments where signal reliability and channel isolation are critical. The isolated channel architecture helps reduce electrical interference between field devices and the control system.\u003c\/p\u003e\n\u003cp\u003eIts 10 ms update cycle supports responsive process monitoring, making it suitable for dynamic applications involving rapid signal variation and continuous measurement tasks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat types of analog signals are supported by the AAV144-S00?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module accepts voltage input ranges including 1 to 5 V and -10 to +10 V.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many input channels are available?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides 16 isolated analog input channels for simultaneous signal acquisition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs the module suitable for electrically noisy environments?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The module includes 1500 VAC isolation between the input side and system circuits to improve operational reliability in industrial installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the input configuration be customized?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Input signal settings can be configured individually across channels 1 through 16 depending on application requirements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44139576328280,"sku":"AAV144-S00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AAV144-S00.jpg?v=1779671618","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aav144-s00-analog-input-module-centum-dcs","provider":"IndustriaX Limited","version":"1.0","type":"link"}