{"product_id":"yokogawa-aal141-h50-analog-input-module-16-channel-module","title":"Yokogawa AAl141-H50 Analog Input Module | 16-Channel Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAl141-H50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module designed for integration with the CENTUM VP distributed control system. This module reliably receives standardized current or voltage signals from 2-wire or 4-wire transmitters and supports dual-redundant configurations for critical process monitoring applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16-channel non-isolated analog input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 4-20mA DC input signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 1-5V DC voltage signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual channel configuration for 2-wire or 4-wire transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransmitter power supply with overcurrent protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast data update period and response time for real-time monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of input channels\u003c\/td\u003e\n\u003ctd\u003e16 (non-isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput signal\u003c\/td\u003e\n\u003ctd\u003e4-20mA DC or 1-5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum allowable input\u003c\/td\u003e\n\u003ctd\u003e27mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput resistance\u003c\/td\u003e\n\u003ctd\u003e400 ohms at 20mA; 1000 ohms (voltage input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower OFF resistance\u003c\/td\u003e\n\u003ctd\u003e500k ohms or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±16 microampere\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData update period\u003c\/td\u003e\n\u003ctd\u003e10 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep response time\u003c\/td\u003e\n\u003ctd\u003e100 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter power supply\u003c\/td\u003e\n\u003ctd\u003e14.8V or higher at 20mA, 26.4V or less at 0mA (current limit: 27mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift due to ambient temperature\u003c\/td\u003e\n\u003ctd\u003e16 microampere per 10 degree Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current consumption\u003c\/td\u003e\n\u003ctd\u003e310mA at 5VDC, 450mA at 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for process monitoring in chemical, oil \u0026amp; gas, and manufacturing industries, where precise signal acquisition and dual-redundant configurations are required for reliable DCS integration.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used with both 2-wire and 4-wire transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes, each channel can be individually configured for either 2-wire or 4-wire operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signals does the module support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 4-20mA current signals and 1-5V DC voltage signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module isolated?\u003c\/strong\u003e\u003cbr\u003eA: The AAl141-H50 module is non-isolated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used in dual redundant setups?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is compatible with dual redundant configurations for high-reliability applications.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44128272679000,"sku":"AAI141-H50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AAI141-H50-3.jpg?v=1779415511","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aal141-h50-analog-input-module-16-channel-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}