{"product_id":"yokogawa-aai841-h00-k4a00-analog-i-o-module-8-channel-hart","title":"Yokogawa AAI841-H00\/K4A00 Analog I\/O Module 8-Channel HART","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Yokogawa is an 8-channel analog input\/output module designed for precise process control applications. This module supports both 4 to 20 mA input and output signals, providing reliable signal acquisition and transmission. Equipped with a KS Cable Interface Adapter, it ensures seamless connectivity in distributed control systems.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis part of the AAI841 series and supports digital communication via HART protocol, enabling integration with advanced monitoring and control platforms. This module is ideal for systems requiring non-isolated, high-accuracy analog signal management.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Analog I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Signal: 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannels: 8 Analog Inputs \/ 8 Analog Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Non-Isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Communication: HART protocol supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface Adapter: KS Cable Interface (Model ATK4A-00)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 55 degrees Celsius (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN Rail \/ Rack Mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 24 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.1% of span typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time: \u0026lt;100 ms for analog signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement: For discontinued\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e, new model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H50\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for process automation tasks in industries such as chemical processing, oil and gas, power generation, and water treatment. It supports precise analog signal monitoring and control in distributed control systems (DCS).\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main difference between AAI841-H00 and AAI841-H50?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eH50 version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the current replacement and may offer updated firmware, improved stability, and enhanced HART communication features, while maintaining backward compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle isolated signals?\u003c\/strong\u003e\u003cbr\u003eA: No, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI841-H00\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis non-isolated. For isolated applications, consider other AAI841 variants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of systems is this module compatible with?\u003c\/strong\u003e\u003cbr\u003eA: It integrates seamlessly with Yokogawa DCS systems and supports standard HART-enabled devices.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44125139173464,"sku":"AAI841-H00\/K4A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AAI841-H00K4A00-2.jpg?v=1779351870","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aai841-h00-k4a00-analog-i-o-module-8-channel-hart","provider":"IndustriaX Limited","version":"1.0","type":"link"}