{"product_id":"yokogawa-aai543-h50-k4a00-analog-output-module-16-channel-hart","title":"Yokogawa AAI543-H50\/K4A00 Analog Output Module 16-Channel HART","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI543-H50\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog output module from Yokogawa, designed for process control systems requiring accurate 4-20 mA output signals. With 16 isolated output channels, the module ensures reliable signal transmission and supports standard switch-over response in redundant configurations. The integrated HART digital communication provides remote configuration, diagnostics, and monitoring capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI543-H50\/K4A00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16 isolated output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signal range: 4-20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard switch-over response for redundant operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART protocol digital communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with KS Cable Interface Adapter (for AEA4D terminal board, Model ATK4A-00)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBasic type, no explosion protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC between output and system for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 750 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit-Open Detection\u003c\/td\u003e\n\u003ctd\u003eLess than 0.65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±48 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e±16 uA per 10 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e230 mA at 5 V DC, 540 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Communication\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, MIL connector, dedicated KS1 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eKS Cable Interface Adapter compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eIdeal for distributed control systems, process automation, and SCADA integration. Common industries include chemical, oil and gas, water treatment, and power plants. The module is particularly suited for redundant configurations where high reliability is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for explosive environments?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI543-H50\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis not rated for explosion protection; select a certified model if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all channels communicate using HART?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all 16 channels support HART for remote configuration and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What interface is required to connect the terminal board?\u003c\/strong\u003e\u003cbr\u003eA: The module uses a KS Cable Interface Adapter compatible with the AEA4D terminal board (Model ATK4A-00).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimilar Models Comparison\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAAI543-H30\u003c\/strong\u003e: Non-HART version, same channel count and output range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAAI543-H60\u003c\/strong\u003e: HART version with enhanced redundancy and optional explosion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44115672563800,"sku":"AAI543-H50\/K4A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AAI543-H50K4A00-3.jpg?v=1779244101","url":"https:\/\/www.industriaxplc.com\/products\/yokogawa-aai543-h50-k4a00-analog-output-module-16-channel-hart","provider":"IndustriaX Limited","version":"1.0","type":"link"}