{"product_id":"tsxmap1074-schneider-electric-communication-module","title":"TSXMAP1074 | Schneider Electric Communication Module","description":"\u003ch2\u003eSchneider Electric TSXMAP1074 Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for industrial data exchange within Modicon TSX Series 7 PLC architectures, the \u003cstrong\u003eSchneider Electric TSXMAP1074\u003c\/strong\u003e (\u003cstrong\u003eTSXMAP1074\u003c\/strong\u003e Mapway Communication Module) provides direct physical\/electrical execution for multi-protocol communication bridging across MAPWAY, Modbus RTU, and Modbus ASCII networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXMAP1074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.16 kg (2.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eMAPWAY, Modbus RTU, Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Role\u003c\/td\u003e\n\u003ctd\u003eMaster\/Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Compatibility\u003c\/td\u003e\n\u003ctd\u003eTSX Series 7 Modular PLCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSchneider Electric PLC Backplane and Deterministic Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe TSXMAP1074 integrates into Modicon TSX Series 7 architectures using backplane bus communication mechanisms that coordinate cyclic data exchange between communication modules and CPU racks. Ethernet-linked MAPWAY and Modbus frames are scheduled through deterministic scan cycles, ensuring bounded latency under master\/slave arbitration. Firmware-level compatibility is aligned with legacy TSX rack addressing, supporting mixed-protocol routing without altering PLC task execution timing or I\/O scan sequencing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does TSXMAP1074 support simultaneous MAPWAY and Modbus operation?\u003cbr\u003eA: Yes. The module supports concurrent protocol handling through internal channel multiplexing, with arbitration controlled by PLC scan cycle timing.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap supported during operation?\u003cbr\u003eA: No hot-swap behavior is defined for TSX Series 7 racks. Module replacement requires power isolation of the rack backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What is the role of Ethernet in this module?\u003cbr\u003eA: Ethernet is used as a physical transport layer for MAPWAY communication encapsulation and Modbus gateway routing within the PLC network structure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be mounted on a standard DIN rail within a TSX Series 7 rack enclosure. Ensure correct seating on the backplane connector to maintain signal integrity across communication lanes. Shielded Ethernet cabling must be grounded at a single-point earth reference to minimize loop impedance. Maintain separation between communication wiring and high-voltage conductors to reduce induced noise coupling. Verify terminal torque and rack alignment before energization.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44266284253272,"sku":"TSXMAP1074","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXMAP1074-2.jpg?v=1782118889","url":"https:\/\/www.industriaxplc.com\/products\/tsxmap1074-schneider-electric-communication-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}