{"product_id":"tsxetg100-schneider-electric-connexium-ethernet-modbus-gateway-router","title":"TSXETG100 Schneider Electric ConneXium Ethernet Modbus Gateway\/Router","description":"\u003ch2\u003eSchneider Electric 140NOE77111 ConneXium Ethernet Modbus Gateway\/Router\u003c\/h2\u003e\n\u003cp\u003eConfigured for Modbus protocol conversion in ConneXium networking architectures, the \u003cstrong\u003eSchneider Electric 140NOE77111\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXETG100\u003c\/strong\u003e Ethernet Modbus gateway\/router, provides direct physical\/electrical execution. This hardware component interfaces up to 32 Modbus serial link devices with standard Ethernet networks via 10BASE-T\/100BASE-TX communication channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 mm x 81 mm x 76 mm (2.83 in x 3.19 in x 2.99 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC [Us] rated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Connected Devices\u003c\/td\u003e\n\u003ctd\u003e32 Modbus serial link devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003e1 x Ethernet 10BASE-T\/100BASE-TX port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e3 LEDs serial link (RS485, RX, TX), 4 LEDs Ethernet (LK, RX, TX, 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95 % at 40 degC (104 degF) without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eSymmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 55022 FCC class A, EN 61000-4-2\/3\/4\/5\/6\/8, EN 61000-6-2, UL 508, CSA C22.2 No 14-M91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, CUL, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet network deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe 140NOE77111 ensures high-throughput synchronization across ConneXium segments, implementing deterministic protocol framing for Web server Class B10 and Class C30 data transfers. The integrated firmware manages communication latency and packet routing over Ethernet 10BASE-T\/100BASE-TX physical layers without performance degradation. This determinism mitigates collisions on the RS485 serial network and guarantees predictable execution sequences during concurrent requests from multiple Modbus masters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the device capacity limit for the serial bus interface?\u003c\/p\u003e\n\u003cp\u003eA: The gateway supports a maximum of 32 connected Modbus serial link devices over the RS485 physical interface.\u003c\/p\u003e\n\u003cp\u003eQ: How is the Web server capability classified for this module?\u003c\/p\u003e\n\u003cp\u003eA: The module is specified with a Class B10 Web server classification and a Class C30 Ethernet network TCP\/IP module profile.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Orientation:\u003c\/strong\u003e Mount the module onto a symmetrical standard DIN rail in a horizontal orientation to maintain structural stability and optimize thermal dissipation profile within the IP30 enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Ensure a direct low-impedance electrical bond between the DIN rail and the functional earth system. Shielded twisted-pair (STP) cabling must be utilized for both Ethernet and RS485 serial links to suppress electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Hookup:\u003c\/strong\u003e Connect a regulated 24 V DC power source to the designated terminals. Verify that all wiring complies with terminal torque ratings to prevent localized overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44269510492248,"sku":"TSXETG100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXETG100-3.jpg?v=1782203589","url":"https:\/\/www.industriaxplc.com\/products\/tsxetg100-schneider-electric-connexium-ethernet-modbus-gateway-router","provider":"IndustriaX Limited","version":"1.0","type":"link"}