{"product_id":"terminal-board-for-analog-yokogawa-aea4d-06-analog-input-modules","title":"Terminal Board for Analog | Yokogawa AEA4D-06 Analog Input Modules","description":"\u003ch2\u003eYokogawa AEA4D-06 Terminal Board for Analog\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AEA4D-06\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAEA4D\u003c\/strong\u003e Terminal Board for Analog, operates as a dedicated hardware component for connecting 16-channel analog I\/O signals within CENTUM VP and CENTUM CS 3000 DCS platforms. It provides direct physical interface execution for Yokogawa FIO analog modules and ensures channel-to-channel isolation for signal integrity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eAEA4D-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eNegligible (passive terminal board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eM4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Configuration\u003c\/td\u003e\n\u003ctd\u003e16 points x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Interface Cable\u003c\/td\u003e\n\u003ctd\u003eKS1 Signal Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 MOhm or greater at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eDCS Signal Integrity Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AEA4D-06 ensures \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e between analog signals to prevent cross-talk and interference in multi-channel configurations. The ISA Standard G3 conformal coating provides corrosion resistance against industrial gases, maintaining stable 4-20 mA HART loop measurements over time. The terminal board supports single and dual-redundant FIO configurations, ensuring continuity of analog signal paths during module replacement or maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Can the AEA4D-06 be hot-swapped while the DCS is online?\u003cbr\u003eA: No, the terminal board is a passive connection interface. Field modules can be replaced under hot-swap procedures, but the board itself must remain wired during operation.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Does the terminal board support explosion-proof environments?\u003cbr\u003eA: No, the -06 suffix indicates ISA G3 coating but explicitly \u003cstrong\u003eno explosion protection\u003c\/strong\u003e, suitable for non-hazardous locations only.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: What is the expected signal isolation between channels?\u003cbr\u003eA: Channel-to-channel isolation follows standard DCS analog separation practices; typical insulation resistance is 100 MOhm at 500 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMount the terminal board on a standard 19-inch rack using M4 fasteners.\u003c\/li\u003e\n\u003cli\u003eRoute KS1 interface cables in separate trays from high-voltage AC lines to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of shielded cables to the rack chassis to maintain channel-to-channel isolation.\u003c\/li\u003e\n\u003cli\u003eAvoid mechanical stress on screw terminals; torque M4 screws to recommended ranges (~0.5 Nm).\u003c\/li\u003e\n\u003cli\u003eInspect conformal coating integrity if the board is installed in environments with corrosive gases.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44152991711320,"sku":"AEA4D-06","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AEA4D-06-3.jpg?v=1780025061","url":"https:\/\/www.industriaxplc.com\/products\/terminal-board-for-analog-yokogawa-aea4d-06-analog-input-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}