{"product_id":"tb825-3bse036634r1-optical-media-converter-abb-advant-s800-i-o","title":"TB825 3BSE036634R1 Optical Media Converter ABB Advant S800 I\/O","description":"\u003ch2\u003eABB TB825 3BSE036634R1 Optical Media Converter\u003c\/h2\u003e\n\u003cp\u003eConfigured for optical signal conversion in the ABB Modulebus network, the \u003cstrong\u003eABB TB825 3BSE036634R1\u003c\/strong\u003e (\u003cstrong\u003eTB825\u003c\/strong\u003e Optical Media Converter) provides direct physical data transmission conversion between electrical and optical communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB825 3BSE036634R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOptical Media Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.2 x 5.1 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModulebus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eSlave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e96 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (+32 to +131 deg F), approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (-40 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Approval\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModulebus Optical Communication Conversion\u003c\/h3\u003e\n\u003cp\u003eThe ABB TB825 3BSE036634R1 performs optical media conversion within ABB industrial control architectures using Modulebus communication. Therefore, the module transfers communication signals through optical interfaces to support extended network connections and electrical isolation between connected segments.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the TB825 operates as a slave device on the Modulebus network. The module supports a 24 VDC power input with a typical current consumption of 96 mA and does not provide line redundancy functionality.\u003c\/p\u003e\n\u003cp\u003eFor ABB automation platforms, communication performance depends on the Modulebus configuration, connected controller capacity, and installed firmware compatibility. Furthermore, the optical conversion function helps separate communication segments where electrical signal transmission limitations exist.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocol does the ABB TB825 3BSE036634R1 support?\u003cbr\u003eA: The TB825 supports the ABB Modulebus communication protocol and operates as a slave device within the network structure.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TB825 provide redundant communication lines?\u003cbr\u003eA: No. The TB825 specification indicates that line redundancy is not supported.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply is required for the TB825 module?\u003cbr\u003eA: The TB825 requires a 24 VDC supply and consumes approximately 96 mA under typical operating conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TB825 module according to the ABB system hardware configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply polarity matches the module connection specification before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eRoute optical communication cables separately from high-voltage power cables to reduce electromagnetic interference risks.\u003c\/li\u003e\n\u003cli\u003eMaintain proper optical connector cleanliness because contamination can affect signal transmission quality.\u003c\/li\u003e\n\u003cli\u003eConfirm hazardous location requirements before installation in classified areas.\u003c\/li\u003e\n\u003cli\u003eEnsure the ambient temperature and humidity remain within the specified operating limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44632747311192,"sku":"TB825 3BSE036634R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TB825-3BSE036634R1-3_1200x1200_1464db61-fb9e-4f23-a1f1-0a839a5fa364.jpg?v=1787297660","url":"https:\/\/www.industriaxplc.com\/products\/tb825-3bse036634r1-optical-media-converter-abb-advant-s800-i-o","provider":"IndustriaX Limited","version":"1.0","type":"link"}