{"product_id":"ssc60d-f2542-node-interface-module-yokogawa","title":"SSC60D-F2542 Node Interface Module | Yokogawa","description":"\u003ch2\u003eYokogawa SSC60D-F2542 Node Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SSC60D-F2542\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSSC601\u003c\/strong\u003e Node Interface Module, operates as a dedicated hardware component for field I\/O communication management within CENTUM VP and ProSafe-RS systems. It executes cyclic data exchange between controllers and I\/O modules, supporting redundant operation and hot-swap replacement.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm W x 266 mm H x 399.2 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorageTemp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerSupply\u003c\/td\u003e\n\u003ctd\u003e24 V DC from FIO baseplate, dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5-8 W depending on hardware revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/OScanCycle\u003c\/td\u003e\n\u003ctd\u003e1-10 ms deterministic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDataRefreshRate\u003c\/td\u003e\n\u003ctd\u003eHigh-speed cyclic communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eBus interface and internal circuits isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMCCompliance\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalIOCapacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 safety I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNodeExpansion\u003c\/td\u003e\n\u003ctd\u003eUp to 9 nodes via SEC401, up to 13 via SEC402 with CFS1350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 4-20 mA HART loop protocol integration for analog field instruments.\u003c\/li\u003e\n\u003cli\u003eChannel-to-channel isolation ensures minimal interference between adjacent I\/O modules.\u003c\/li\u003e\n\u003cli\u003eCompatible with FOUNDATION Fieldbus and PROFIBUS PA connectivity for mixed network environments.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJc) applied for accurate thermocouple measurements under variable ambient temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Does the SSC60D-F2542 support hot-swap replacement for I\/O modules?\u003cbr\u003eA: Yes. Both the Node Interface Module and I\/O modules on the baseplate can be replaced without shutting down the controller or field node.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum I\/O scan cycle achievable?\u003cbr\u003eA: Deterministic scan cycles range from 1 to 10 ms depending on node configuration and connected I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: Can firmware updates be applied without disrupting ongoing communication?\u003cbr\u003eA: Firmware can be upgraded while maintaining cyclic data exchange if redundant modules are installed; otherwise, temporary communication suspension occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a standard 19-inch rack using all specified M5 screws to maintain mechanical stability.\u003c\/li\u003e\n\u003cli\u003eEnsure shielded network cabling (CAT5e or higher) is properly grounded to prevent EMC issues.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between power and communication lines to reduce crosstalk and signal degradation.\u003c\/li\u003e\n\u003cli\u003eAvoid obstructing the built-in fan unit to guarantee correct cooling; maintain at least 50 mm clearance above and behind the module.\u003c\/li\u003e\n\u003cli\u003eObserve polarity when connecting the 24 V DC power inputs; use dual-redundant supplies to support uninterrupted operation.\u003c\/li\u003e\n\u003cli\u003eRoute ESB bus cabling according to the node topology; limit the distance between nodes as per SEC401\/SEC402 specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44163201040472,"sku":"SSC60D-F2542","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/SSC60D-F2542.jpg?v=1780283973","url":"https:\/\/www.industriaxplc.com\/products\/ssc60d-f2542-node-interface-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}