{"product_id":"sdv144-s13-b4d10-yokogawa-digital-i-o-module-datasheet-technical-manual","title":"SDV144-S13\/B4D10 Yokogawa Digital I\/O Module Datasheet \u0026 Technical Manual","description":"\u003ch1\u003eYokogawa SDV144-S13\/B4D10 Digital Input\/Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for discrete signal acquisition and actuation in ProSafe-RS safety control architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SDV144-S13S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eSDV144\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input\/Output Module) provides direct physical\/electrical execution of 12 to 24 VDC field signals within safety I\/O backplane environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eModel designation SDV144-S13S1 is a single defined ordering code. No validated structural decomposition beyond base module family (SDV144) is available from provided data. No further suffix segmentation is applied.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSDV144-S13S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital input, sinking or sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e-5 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDigital output, sinking or sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Diagnostic Layering\u003c\/h3\u003e\n\u003cp\u003eThe SDV144-S13S1 implements per-channel optical isolation to decouple field-side electrical disturbances from internal logic domains. This isolation structure reduces susceptibility to ground potential differences and transient coupling between adjacent channels in high-density I\/O configurations.\u003c\/p\u003e\n\u003cp\u003eIntegrated diagnostic routines continuously evaluate input state integrity, output switching response, and internal communication status. Fault localization is performed at channel granularity, enabling isolation of single-point wiring or device-level failures without full module replacement.\u003c\/p\u003e\n\u003cp\u003eWithin ProSafe-RS architectures, the module participates in deterministic safety I\/O exchange cycles, where scan timing and signal validation are synchronized with controller-level safety logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SDV144-S13S1 support hot-swap under live backplane power conditions?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap behavior is system-dependent and governed by the ProSafe-RS chassis configuration. The module itself interfaces through a backplane connector and does not autonomously manage insertion transients.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are all 16 channels independently isolated?\u003c\/strong\u003e\u003cbr\u003eA: Each channel is optically isolated at the signal interface level, minimizing cross-channel electrical interference and limiting fault propagation between I\/O points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum switching rate supported per channel?\u003c\/strong\u003e\u003cbr\u003eA: Switching performance is constrained by system scan cycle timing and backplane communication rate (up to 10 Mbps), rather than a fixed per-channel mechanical limit.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44139689640024,"sku":"SDV144-S13\/B4D10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/SDV144-S13B4D10.jpg?v=1779675939","url":"https:\/\/www.industriaxplc.com\/products\/sdv144-s13-b4d10-yokogawa-digital-i-o-module-datasheet-technical-manual","provider":"IndustriaX Limited","version":"1.0","type":"link"}