{"product_id":"schneider-electric-tsxscpcm4030-rs422-rs485-tap-link-cable","title":"Schneider Electric TSXSCPCM4030 RS422\/RS485 Tap Link Cable","description":"\u003ch2\u003eSchneider Electric TSXSCPCM4030 RS422\/RS485 Tap Link Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated RS422\/RS485 tap link communication in Modicon Premium Automation Platform Modbus character-mode networks, the \u003cstrong\u003eSchneider Electric TSXSCPCM4030\u003c\/strong\u003e (\u003cstrong\u003eTSXSCPCM4030\u003c\/strong\u003e Modbus connecting cable) provides direct physical layer interconnection between field devices and passive junction termination assemblies. The assembly implements flying-lead termination for RS422\/RS485 signal routing over a 3 m fixed-length harness.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTSXSCPCM4030: Fixed-order cable assembly identifier\u003c\/li\u003e\n\u003cli\u003eTSXSCPC: Modicon Premium communication cable family (RS422\/RS485 tap link)\u003c\/li\u003e\n\u003cli\u003eM4030: 3 m harness length designation within tap link cable set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric TSXSCPCM4030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 190 x 30 mm (package)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003ePassive component, no power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eFlying leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus (Character Mode), RS422\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eTSXSCA50, TSXSCP114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNo corrosive gases, 95 percent RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eSchneider Electric Industrial Control Communication Interface Characteristics\u003c\/h2\u003e\n\u003cp\u003eThe TSXSCPCM4030 is implemented within Schneider Electric Modicon Premium communication architecture as a passive RS422\/RS485 tap link element. In PLC backplane-based distributed I\/O topologies, the cable assembly maintains deterministic signal propagation integrity between Modbus character-mode nodes.\u003c\/p\u003e\n\u003cp\u003eWithin RS485 differential signaling layers, impedance continuity and common-mode noise rejection are maintained through controlled passive junction routing. The flying-lead termination structure is intended for field termination into TSXSCA50 and TSXSCP114 interface points, ensuring consistent electrical reference alignment across serial multidrop networks.\u003c\/p\u003e\n\u003cp\u003eBackplane-integrated communication timing behavior remains dependent on Modicon Premium CPU scan cycle synchronization and Modbus master polling intervals, with no embedded signal conditioning or active isolation circuitry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does TSXSCPCM4030 include active signal conditioning or isolation?\u003cbr\u003eA: No. The assembly is a passive RS422\/RS485 tap link cable with flying leads and no electronic components.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be used in full-duplex RS422 configurations?\u003cbr\u003eA: Yes, provided the system architecture supports RS422 signaling and compatible Modicon Premium interface modules are used.\u003c\/p\u003e\n\u003cp\u003eQ: Does the cable introduce measurable communication latency?\u003cbr\u003eA: No active latency is introduced. Signal delay is limited to propagation delay of the 3 m copper conductor length.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure RS422\/RS485 differential pairs are maintained as twisted and correctly polarized during termination\u003c\/li\u003e\n\u003cli\u003eAvoid running the cable parallel to high-voltage or high-frequency switching conductors to reduce EMI coupling\u003c\/li\u003e\n\u003cli\u003eConnect flying leads only to compatible TSXSCA50 or TSXSCP114 termination points\u003c\/li\u003e\n\u003cli\u003eMaintain proper shield grounding strategy at a single reference point in Modbus multidrop networks\u003c\/li\u003e\n\u003cli\u003eVerify continuity and polarity before commissioning to prevent bus communication errors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44266393632856,"sku":"TSXSCPCM4030","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXSCPCM4030-3.jpg?v=1782120980","url":"https:\/\/www.industriaxplc.com\/products\/schneider-electric-tsxscpcm4030-rs422-rs485-tap-link-cable","provider":"IndustriaX Limited","version":"1.0","type":"link"}