{"product_id":"schneider-electric-tsxdst1682-output-module","title":"Schneider Electric TSXDST1682 | Output Module","description":"\u003ch1\u003eSchneider Electric TSX DST 1632 Output Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TSXDST1632\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealso cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSX DST 1632 Relay Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a discrete output hardware component for digital actuation control within Modicon TSX PLC backplane architectures. It provides direct electrical switching via relay contacts across 16 output points arranged in modular grouped configuration.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo structured suffix segmentation is defined for TSX DST 1632. The model is treated as a single fixed ordering code without field-expandable option encoding.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric TSXDST1632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (derating above 40 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e12 V: 25 mA; 12 Vp: 38 mA per point at logic state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay output, 16 channels (4 groups of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load\u003c\/td\u003e\n\u003ctd\u003e24 VDC; resistive 0.2 W to 50 W; inductive 0.2 W to 25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eOFF-\u0026gt;ON max 15 ms; ON-\u0026gt;OFF max 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003eMax 0.2 mA at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10 V to 30 V (including ripple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Level\u003c\/td\u003e\n\u003ctd\u003ePositive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eWithin Modicon TSX rack systems, the TSX DST 1632 integrates via deterministic backplane signaling, where output refresh cycles are synchronized with PLC scan execution. I\/O density scaling is handled through grouped 4-point relay banks, reducing address fragmentation in TSX configuration memory. Compatibility with TSX DET 16 12 input modules ensures consistent channel mapping across mixed discrete I\/O racks. Signal propagation is constrained by internal relay actuation latency rather than network jitter, maintaining fixed scan-to-output determinism under firmware-controlled cycle timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the TSX DST 1632 outputs be hot-swapped during operation?\u003cbr\u003eA: No hot-swap capability is defined. Module insertion\/removal must be performed under de-energized rack conditions to avoid backplane signal disturbance.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of inductive loads on output switching behavior?\u003cbr\u003eA: Inductive loads up to specified limits require suppression (flyback diode or RC snubber) to maintain relay contact integrity and limit overvoltage stress.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support mixed AC\/DC load switching?\u003cbr\u003eA: The relay contacts are electrically passive switching elements; load compatibility is determined by contact rating limits rather than internal polarity constraints.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure rack power is isolated before module insertion into TSX backplane slots. Verify correct alignment of edge connector pins to prevent bent terminal contacts. Maintain separation between output wiring and high-frequency or power conductors to minimize inductive coupling. Shielded cable grounding should be terminated at a single chassis reference point to avoid ground loop currents. Relay output wiring should respect current derating curves for elevated ambient temperatures above 40 degC.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44245547024472,"sku":"TSXDST1682","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXDST1682-2.jpg?v=1781589005","url":"https:\/\/www.industriaxplc.com\/products\/schneider-electric-tsxdst1682-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}