{"product_id":"schneider-electric-tsxbly01-screw-connection-terminal-block","title":"Schneider Electric TSXBLY01 Screw Connection Terminal Block","description":"\u003ch2\u003eSchneider Electric TSXBLY01 Screw Connection Terminal Block\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete and analog signal termination in Modicon Premium I\/O interfacing, the \u003cstrong\u003eSchneider Electric TSXBLY01\u003c\/strong\u003e (\u003cstrong\u003eTSXBLY01\u003c\/strong\u003e Screw Connection Terminal Block) provides direct physical\/electrical execution between field wiring and compatible analog I\/O modules within Modicon Premium backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eTSXBLY01 is a single-order terminal block designation. No further suffix segmentation or variant encoding is defined in the provided manufacturer data. The model functions as a fixed 20-way screw termination interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric TSXBLY01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg (0.22 lb US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003ePassive component, no power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eScrew Connection Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Ways\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eTSXASY410, TSXAEY414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003eModicon Premium I\/O connection interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eBackplane Interfacing and IO Density Handling Characteristics\u003c\/h2\u003e\n\u003cp\u003eWithin Modicon Premium PLC architectures, TSXBLY01 supports structured I\/O termination density scaling by providing a fixed 20-point screw terminal layout for analog and discrete signal aggregation. Backplane bus communication remains unaffected electrically, as the module functions purely as a passive termination layer between field wiring and I\/O module connectors. Wiring continuity and channel segregation depend on mechanical torque stability and correct terminal assignment mapping.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can TSXBLY01 be hot-swapped while the I\/O module is energized?\u003cbr\u003eA: Mechanical disconnection is possible only after system de-energization. The terminal block itself contains no active circuitry, but removal under live conditions may disrupt field signal integrity at the connected TSXASY410 or TSXAEY414 modules.\u003c\/p\u003e\n\u003cp\u003eQ: Does TSXBLY01 introduce any signal conditioning or isolation?\u003cbr\u003eA: No. It provides direct screw termination without galvanic isolation or signal processing. Isolation is handled at the I\/O module level.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended torque for screw terminals?\u003cbr\u003eA: Manufacturer torque values are not specified in the provided data. Standard industrial control practice applies, ensuring secure conductor clamping without deformation of terminal structures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure all field wiring is fully de-energized before installation. Conductors should be stripped to standard terminal insertion depth and inserted into the correct 20-way assignment positions. Tighten screws uniformly to maintain consistent contact pressure across all channels. Avoid excessive bending stress on conductors near the terminal entry point. Maintain separation between analog signal lines and high-voltage routing to reduce coupling effects. Verify continuity mapping between TSXBLY01 terminals and connected TSXASY410 or TSXAEY414 modules prior to system energization.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44290593914968,"sku":"TSXBLY01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXBLY01-3.jpg?v=1782719370","url":"https:\/\/www.industriaxplc.com\/products\/schneider-electric-tsxbly01-screw-connection-terminal-block","provider":"IndustriaX Limited","version":"1.0","type":"link"}