{"product_id":"schneider-electric-modicon-quantum-140aco13000-analog-output-module","title":"Schneider Electric Modicon Quantum 140ACO13000 Analog Output Module","description":"\u003ch2\u003eSchneider Electric 140ACO13000 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog current output signal generation in Modicon Quantum backplane I\/O network, the \u003cstrong\u003eSchneider Electric 140ACO13000\u003c\/strong\u003e (\u003cstrong\u003e140ACO13000 Analog Output Module\u003c\/strong\u003e) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric 140ACO13000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5 W max dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Channels\u003c\/td\u003e\n\u003ctd\u003e8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 0-25 mA, 4-20 mA current loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0-20000 \/ 0-25000 \/ 0-16000 \/ 0-4095 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Voltage\u003c\/td\u003e\n\u003ctd\u003e6-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1780 V AC for 1 minute (channel to bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling Time\u003c\/td\u003e\n\u003ctd\u003e1.6 ms to 5 percent, 3.2 ms to 0.1 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.2 percent full scale at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.004 percent FS per degC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Control Behavior\u003c\/h3\u003e\n\u003cp\u003eWithin the Schneider Electric Modicon Quantum architecture, the 140ACO13000 module exchanges output words via the backplane I\/O bus with 8-word addressing allocation. The deterministic scan cycle is synchronized with Quantum rack communication timing, ensuring fixed update behavior independent of field load conditions. Firmware-level backplane arbitration manages channel refresh sequencing across all 8 analog outputs without inter-channel timing skew beyond module update time limits. Channel scaling is executed locally, reducing controller-side computational overhead during cyclic task execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module outputs be configured independently per channel?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Each of the 8 channels supports independent range selection including 0-20 mA, 0-25 mA, or 4-20 mA scaling mapped into digital counts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens under open loop conditions in 4-20 mA mode?\u003c\/strong\u003e\u003cbr\u003eA: The module implements open-circuit detection and flags a channel fault via diagnostic LED and bus status bit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swap supported on the Quantum backplane for this module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports rack insertion\/removal according to Quantum backplane rules; field loop current should be removed prior to module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMaintain shield continuity for all analog current loops and terminate cable shielding at a single reference ground point to prevent ground loop formation. Ensure loop power supply remains within 6-30 V DC under full load conditions across all 8 channels. Backplane connector seating must be fully engaged to guarantee stable 1780 V AC isolation integrity. Avoid routing analog output conductors parallel to high-frequency switching lines or motor drive cabling to reduce induced coupling noise on 4-20 mA loops.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44224027459672,"sku":"140ACO13000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140ACO13000.jpg?v=1781231011","url":"https:\/\/www.industriaxplc.com\/products\/schneider-electric-modicon-quantum-140aco13000-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}