{"product_id":"schneider-connexium-499nos17100-ethernet-switch","title":"Schneider 499NOS17100 ConneXium Industrial Ethernet Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider 499NOS17100 is a high-performance industrial Ethernet switch engineered for the ConneXium cabling system. This managed hardware solution is designed to facilitate robust local area network connectivity in challenging industrial environments. Featuring a hybrid port configuration, it bridges standard copper-based instrumentation with high-speed fiber-optic plant backbones. By providing reliable 10\/100 Mbps data transmission, this switch ensures consistent communication across automated control nodes, effectively minimizing network jitter and reducing the risk of data transmission failures in critical production cycles.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHybrid Architecture: Equipped with 5 twisted-pair copper (TX) ports and 2 fiber-optic (FX) ports for versatile network integration.\u003c\/li\u003e\n\u003cli\u003eAuto-Negotiation: RJ45 ports support auto-MDI\/MDIX crossover detection, simplifying the installation process.\u003c\/li\u003e\n\u003cli\u003eLong-Distance Connectivity: Dual fiber-optic channels allow for extended transmission distances without the need for signal repeaters.\u003c\/li\u003e\n\u003cli\u003ePassive Cooling: The fanless, industrial-grade enclosure design prevents dust ingress and mechanical failure, promoting long-term reliability.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Monitoring: Integrated front-panel LED indicators provide real-time status updates on link activity, data speed, and power supply health.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis switch is suitable for high-interference industrial settings, including water treatment facilities, power distribution substations, oil and gas refineries, and mining infrastructure. It is specifically designed to support deterministic control communication where network stability is essential for process safety and uptime.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e499NOS17100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eConneXium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e5 x RJ45 (TX), 2 x Fiber (FX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMounting: Ensure the device is installed in a well-ventilated enclosure to maintain optimal operating temperatures.\u003c\/li\u003e\n\u003cli\u003eGrounding: Always connect the device chassis to a common earth ground to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eWiring: Use shielded Ethernet cabling in high-EMI environments to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003ePower: Verify that the 24 VDC power source is stable and within the specified range before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eSafety: Power down the system before performing any hardware connections or maintenance to prevent electrical shorts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this switch support auto-crossover?\u003c\/strong\u003e Yes, the 5 copper ports feature auto-MDI\/MDIX, which automatically detects and adjusts for straight-through or crossover cable connections.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary power requirement?\u003c\/strong\u003e The unit operates on a 24 VDC power supply with a typical consumption of 6.5 W.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44701584195672,"sku":"499NOS17100","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_e364f51e-5fd3-49a8-a038-1aedf47d6bac.jpg?v=1788383143","url":"https:\/\/www.industriaxplc.com\/products\/schneider-connexium-499nos17100-ethernet-switch","provider":"IndustriaX Limited","version":"1.0","type":"link"}