{"product_id":"safe-loop-monitored-digital-output-module-honeywell-fs-sdol-0424","title":"Safe Loop-Monitored Digital Output Module | Honeywell FS-SDOL-0424","description":"\u003ch2\u003eHoneywell FS-SDOL-0424 Safe Loop-Monitored Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for loop-monitored digital output execution in Honeywell Safety Manager systems, the \u003cstrong\u003eHoneywell FS-SDOL-0424\u003c\/strong\u003e (\u003cstrong\u003eFS-SDOL-0424\u003c\/strong\u003e Safe Loop-Monitored Digital Output Module) provides direct physical switching control for 24 VDC field loads through four monitored output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SDOL-0424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Loop-Monitored Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 x 19 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC system supply, 24 VDC output supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (= 4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Total Module Load\u003c\/td\u003e\n\u003ctd\u003e3.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Inductance\u003c\/td\u003e\n\u003ctd\u003e0.5 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.3 V at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Monitoring Functions\u003c\/td\u003e\n\u003ctd\u003eLead breakage detection, output short circuit monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad De-energization\u003c\/td\u003e\n\u003ctd\u003eSupported through primary and secondary means\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Loop Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FS-SDOL-0424 performs safe digital output control with loop monitoring functions for field actuator circuits. Furthermore, the module detects abnormal output conditions including external wiring lead breakage and output short circuits.\u003c\/p\u003e\n\u003cp\u003eThe module supports de-energization through secondary means, which allows the safety system to force field outputs into a defined safe state. Additionally, suppression diodes manage inductive load behavior and reduce electrical disturbances during switching operations.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell Safety Manager applications, output monitoring maintains channel status visibility while limiting cross-talk effects between output circuits. The design supports 24 VDC field devices with a maximum channel current of 1 A and a total module load capacity of 3.6 A.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field devices can the FS-SDOL-0424 control?\u003cbr\u003eA: The FS-SDOL-0424 controls 24 VDC field loads through four digital output channels with loop monitoring functions.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect field wiring faults?\u003cbr\u003eA: The module monitors output circuits and detects conditions such as external output wiring lead breakage and output short circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical limits apply to connected loads?\u003cbr\u003eA: Each channel supports up to 1 A current, while the complete module supports a maximum load of 3.6 A with specified inductive and capacitive load limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FS-SDOL-0424 in the designated Honeywell Safety Manager rack position according to system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC field supply polarity before connecting output wiring.\u003c\/li\u003e\n\u003cli\u003eSeparate output signal wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to site grounding practices and safety system installation standards.\u003c\/li\u003e\n\u003cli\u003eConfirm actuator wiring continuity before enabling output operation.\u003c\/li\u003e\n\u003cli\u003eCheck field load characteristics to ensure inductance and capacitance values remain within module specifications.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections periodically for mechanical looseness or oxidation in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44382072897624,"sku":"FS-SDOL-0424","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FS-SDOL-0424-3.jpg?v=1784099254","url":"https:\/\/www.industriaxplc.com\/products\/safe-loop-monitored-digital-output-module-honeywell-fs-sdol-0424","provider":"IndustriaX Limited","version":"1.0","type":"link"}