{"product_id":"pm851k01-3bse018168r1-abb-ac-800m-profibus-dp-interface-module","title":"PM851K01 3BSE018168R1 ABB AC 800M Profibus DP Interface Module","description":"\u003ch2\u003eABB CI851K01 3BSE018168R1 Profibus DP Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI851K01 3BSE018168R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI851K01\u003c\/strong\u003e Profibus DP Interface Module, operates as a dedicated communication component for PROFIBUS DP data exchange within ABB control system platforms. It provides the physical interface between ABB controller environments and connected PROFIBUS DP field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI851K01 3BSE018168R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProfibus DP Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB Advant Controller \/ AC 800M related control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE018168R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.5 x 6.5 x 12.7 cm (shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Network Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CI851K01 manages PROFIBUS DP communication between ABB controller systems and distributed field devices. Therefore, it handles cyclic process data transfer, diagnostic information exchange, and device communication management through the PROFIBUS DP protocol structure.\u003c\/p\u003e\n\u003cp\u003eThe module supports ABB industrial control architectures that require deterministic fieldbus communication. In addition, the interface module integrates with ABB controller backplane communication, allowing I\/O data from PROFIBUS DP devices to enter the control application environment.\u003c\/p\u003e\n\u003cp\u003eThe CI851K01 contributes to I\/O density scaling by enabling connection of multiple PROFIBUS DP nodes through a standardized industrial network. Furthermore, proper configuration of controller firmware and communication parameters is required to maintain compatibility within the installed ABB automation platform.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocol does the ABB CI851K01 support?\u003cbr\u003eA: The CI851K01 supports PROFIBUS DP communication for exchanging process data and diagnostics between ABB control systems and connected field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CI851K01 be installed without ABB controller configuration changes?\u003cbr\u003eA: No. The module requires configuration within the ABB engineering environment, including PROFIBUS DP network parameters and connected device definitions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CI851K01 support direct connection to Ethernet-based field networks?\u003cbr\u003eA: No. The CI851K01 is designed for PROFIBUS DP communication and does not provide direct Ethernet network conversion functionality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CI851K01 according to ABB controller rack and module positioning requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the backplane connection is correctly seated before applying system power.\u003c\/li\u003e\n\u003cli\u003eUse PROFIBUS DP cables with appropriate shielding and characteristic impedance specifications.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding design to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate PROFIBUS communication wiring from high-voltage power cables and strong electromagnetic sources.\u003c\/li\u003e\n\u003cli\u003eConfirm PROFIBUS node addressing and communication parameters before system commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck diagnostic indicators after installation to verify network communication status.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44661817409624,"sku":"PM851K01 3BSE018168R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/PM851K01-3BSE018168R1-3_1200x1200_5db77b68-506d-4847-b17e-4cd42118915f.jpg?v=1787736625","url":"https:\/\/www.industriaxplc.com\/products\/pm851k01-3bse018168r1-abb-ac-800m-profibus-dp-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}