{"product_id":"nfcp501-s05-s1-field-control-processor-module-yokogawa","title":"NFCP501-S05 S1 Field Control Processor Module | Yokogawa","description":"\u003ch2\u003eYokogawa NFCP501-S05 S1 Field Control Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP501-S05 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFCP501\u003c\/strong\u003e Field Control Processor Module, operates as a dedicated hardware component for executing control logic and managing I\/O communications within the CENTUM VP Distributed Control System.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eNFCP501-S05 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm × 130 mm × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 2.5 A–3.0 A (full station load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessorType\u003c\/td\u003e\n\u003ctd\u003e32-bit Industrial Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemoryConfiguration\u003c\/td\u003e\n\u003ctd\u003eECC RAM \u0026amp; Non-volatile Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlCycleTime\u003c\/td\u003e\n\u003ctd\u003eConfigurable, typically 50 ms or 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicationInterface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP 1000Base-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancySupport\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSlot-mounted in Yokogawa FCU baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolingMethod\u003c\/td\u003e\n\u003ctd\u003eNatural air circulation (fanless design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Features\u003c\/h3\u003e\n\u003cp\u003eThe NFCP501-S05 S1 provides channel-to-channel isolation to prevent interference between simultaneous control loops. Cold junction compensation (CJC) is supported for temperature input channels to maintain precise readings across thermocouple-based sensors. Integrated 4-20 mA HART loop protocol facilitates digital communication over analog channels without disrupting the signal. FOUNDATION Fieldbus and Profibus PA connectivity are supported through optional gateway interfaces, ensuring seamless network integration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be hot-swapped in a running FCU?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap is supported only if the backup module is active in a dual-redundant configuration. Single-module operation requires a complete system shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the redundancy switch-over time?\u003c\/strong\u003e\u003cbr\u003eA: Switch-over to the redundant module occurs within a few milliseconds, preserving active control loops without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is firmware from a different style code compatible?\u003c\/strong\u003e\u003cbr\u003eA: Only firmware matching the exact style code S1 should be used. Mismatched firmware may prevent synchronization in dual-redundant setups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module in a Yokogawa FCU slot, ensuring firm mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure Vnet\/IP ports are connected using shielded twisted-pair cables with proper grounding to reduce EMI.\u003c\/li\u003e\n\u003cli\u003eMaintain clear airflow around the module; avoid enclosing the unit in sealed compartments to prevent thermal accumulation.\u003c\/li\u003e\n\u003cli\u003eFollow standard industrial ESD precautions during handling and installation.\u003c\/li\u003e\n\u003cli\u003eKeep the module away from high-voltage switching equipment or strong magnetic fields to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219237236824,"sku":"NFCP501-S05 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NFCP501-S05S1.jpg?v=1781144139","url":"https:\/\/www.industriaxplc.com\/products\/nfcp501-s05-s1-field-control-processor-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}