{"product_id":"mc-psrx04-51404174-275-honeywell-power-system-assembly","title":"MC-PSRX04 51404174-275 | Honeywell | Power System Assembly","description":"\u003ch2\u003eHoneywell MC-PSRX04 Redundant PM Power System Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for redundant DC power distribution in Honeywell TDC 3000 and High-Performance Process Manager (HPM) platforms, the \u003cstrong\u003eHoneywell MC-PSRX04 (51404174-275)\u003c\/strong\u003e (\u003cstrong\u003eMC-PSRX04\u003c\/strong\u003e Redundant PM Power System Assembly) provides direct electrical power conditioning and load-sharing execution for Process Manager I\/O (PMIO) and Universal Control Network (UCN) systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PSRX04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51404174-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant PM Power System Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ TPS \/ HPM Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.5 kg to 1.0 kg depending on configuration components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e16 A \/ 20 A per output in redundant load-sharing configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on connected load and installed power supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual hot-swappable silver-faced power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Components\u003c\/td\u003e\n\u003ctd\u003ePower supply housing 51404170-175 with compatible power modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Power Distribution and Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MC-PSRX04 assembly provides redundant AC-to-DC power conversion for Honeywell process control hardware. Moreover, the dual power supply arrangement supports load-sharing operation and maintains DC output availability when one supply module requires removal or replacement.\u003c\/p\u003e\n\u003cp\u003eHoneywell PMIO power architectures require stable DC distribution for I\/O subsystem operation. Therefore, the MC-PSRX04 uses independent power supply modules to reduce interruption risk during power module maintenance activities.\u003c\/p\u003e\n\u003cp\u003eThe conformal coating protects circuit assemblies against moisture, dust, and industrial contaminants. In addition, the assembly design supports installation in control environments where electrical continuity and environmental protection requirements apply.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process instrumentation interfaces, the power subsystem supports isolated channel architectures used with analog and digital I\/O modules. The assembly operates as a supporting hardware element rather than a signal processing module, while maintaining the required supply conditions for connected PMIO equipment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MC-PSRX04 support redundant power module replacement during system operation?\u003cbr\u003eA: The assembly is designed with dual power supply modules for redundant operation. Hot-swapping capability depends on the installed power supply model and system maintenance procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What type of environmental protection does the MC-PSRX04 provide?\u003cbr\u003eA: The assembly uses conformal coating to protect internal electronic circuits from humidity, moisture, and industrial contaminants.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MC-PSRX04 operate with Honeywell TDC 3000 and HPM systems?\u003cbr\u003eA: Yes. The module is specified for Honeywell TDC 3000, TPS, and High-Performance Process Manager system environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the installed power supply modules match the MC-PSRX04 assembly configuration before mounting.\u003c\/li\u003e\n\u003cli\u003eInstall the assembly in a controlled cabinet environment with proper ventilation and mechanical support.\u003c\/li\u003e\n\u003cli\u003eConfirm AC input wiring follows site electrical standards before energizing the power system.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between AC power wiring and low-level instrumentation signal cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect protective grounding according to cabinet grounding requirements and Honeywell installation documentation.\u003c\/li\u003e\n\u003cli\u003eInspect connector conditions before installation and ensure all power module interfaces are fully seated.\u003c\/li\u003e\n\u003cli\u003eApply maintenance procedures defined for redundant power systems before removing or replacing supply modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44375837474904,"sku":"MC-PSRX04 51404174-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-PSRX0451404174-275-3.jpg?v=1784013174","url":"https:\/\/www.industriaxplc.com\/products\/mc-psrx04-51404174-275-honeywell-power-system-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}