{"product_id":"is215ucveh2a-ge-mark-vi-vme-controller-card","title":"IS215UCVEH2A GE Mark VI VME Controller Card","description":"\u003ch2\u003eGE IS215UCVEH2A Mark VI VME Controller Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS215UCVEH2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS215UCVEH2A\u003c\/strong\u003e VME Controller Card, operates as a dedicated hardware component for real-time turbine control logic execution within GE Mark VI\/Mark VIe Speedtronic control systems. The board provides processor functions, VME bus communication, and control lane processing for turbine sequencing, protection, and regulation tasks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS215UCVEH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6U VME single-slot form factor; approximately 160 mm x 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, 6 A typical, 8 A maximum; +\/-12 VDC auxiliary supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Celeron 300 MHz processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e32 MB DRAM; Flash and battery-backed NVRAM storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eQNX real-time operating system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eVME64 compliant, A32\/D32 transfer modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10BaseT\/100BaseTX RJ-45 Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eCOM1 serial communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Function\u003c\/td\u003e\n\u003ctd\u003eVME controller and turbine control processor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Method\u003c\/td\u003e\n\u003ctd\u003eBoolean control logic execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eVME Bus and TMR Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IS215UCVEH2A controller card operates within the GE Mark VI turbine control architecture using VME backplane communication. The processor executes control algorithms, sequencing routines, and diagnostic tasks while exchanging data with connected I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe controller supports Triple Modular Redundancy (TMR) operation, where three independent control lanes process and compare voting data. The voting mechanism allows fault detection and continued control execution when a single processing lane experiences a fault condition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of processor is installed on the IS215UCVEH2A?\u003cbr\u003eA: The module uses an Intel Celeron 300 MHz processor and operates with a QNX real-time operating system for deterministic control execution.\u003c\/p\u003e\n\u003cp\u003eQ: What backplane interface does the IS215UCVEH2A support?\u003cbr\u003eA: The controller uses a VME64 compliant interface with A32\/D32 transfer modes for communication with Mark VI system modules.\u003c\/p\u003e\n\u003cp\u003eQ: What power input is required for this controller card?\u003cbr\u003eA: The module requires a +5 VDC supply with approximately 6 A typical current consumption and 8 A maximum current demand, with auxiliary +\/-12 VDC inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS215UCVEH2A controller card into the designated 6U VME rack slot according to the Mark VI cabinet configuration documentation. Verify backplane connector alignment before insertion and ensure rack power is removed during installation or removal.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cables for Ethernet and serial connections where required by the cabinet wiring design. Maintain separation between signal wiring and high-voltage or high-current conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConfirm grounding continuity between the VME rack, cabinet chassis, and protective earth system. Verify firmware compatibility, I\/O module addressing, and controller configuration parameters before system startup.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44387607380056,"sku":"IS215UCVEH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS215UCVEH2A.jpg?v=1784188158","url":"https:\/\/www.industriaxplc.com\/products\/is215ucveh2a-ge-mark-vi-vme-controller-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}