{"product_id":"ics-triplex-t8480-analog-output-tmr-40-channel-module","title":"ICS Triplex T8480 Analog Output TMR 40 Channel Module","description":"\u003ch2\u003eICS Triplex T8480 Analog Output TMR 40 Channel Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 1-22 mA field signal execution in Trusted TMR control system networks, the \u003cstrong\u003eICS Triplex T8480\u003c\/strong\u003e (\u003cstrong\u003eT8480\u003c\/strong\u003e Analog Output TMR 40 Channel Module) provides direct physical and electrical output control for safety instrumented applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output TMR 40 Channel Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3 x 30.2 x 26.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e20 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e40 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e1 to 22 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Output Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Supply Load\u003c\/td\u003e\n\u003ctd\u003e16 W at 22 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Supply Power\u003c\/td\u003e\n\u003ctd\u003e36 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Architecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Safety Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe T8480 module uses triple modular redundancy (TMR) architecture to process analog output commands through redundant internal channels. Therefore, the module maintains output execution through voting logic and fault monitoring mechanisms.\u003c\/p\u003e\n\u003cp\u003eThe module provides 40 analog output channels with a 4-20 mA recommended operating range. Each channel supports controlled field current delivery between 1 and 22 mA, allowing direct interface with analog actuators and field devices.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the T8480 applies galvanic isolation concepts within the safety control architecture to separate field circuits from internal system electronics. This design reduces the effect of field wiring disturbances on controller operation.\u003c\/p\u003e\n\u003cp\u003eThe module supports fail-safe state execution through continuous diagnostic monitoring. In addition, the TMR structure allows the system to identify channel faults and maintain controlled operation according to configured safety logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of output signals does the T8480 provide?\u003cbr\u003eA: The T8480 provides 40 analog output channels with a recommended 4-20 mA current signal range and supports 1 to 22 mA operational field current.\u003c\/p\u003e\n\u003cp\u003eQ: What supply voltage range does the T8480 require?\u003cbr\u003eA: The module operates with a system supply voltage range of 20 to 32 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Does the T8480 support TMR redundancy operation?\u003cbr\u003eA: Yes. The T8480 uses triple modular redundancy (TMR) architecture for safety output processing and diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the T8480 module in the designated Trusted system chassis slot according to the controller hardware configuration requirements.\u003c\/p\u003e\n\u003cp\u003eUse shielded field cables for analog current output wiring where required by the installation environment. Connect cable shields according to site grounding standards to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eSeparate analog output wiring from high-voltage power cables and switching circuits. Maintain proper terminal identification during installation to prevent channel assignment errors.\u003c\/p\u003e\n\u003cp\u003eVerify the system supply voltage before energizing the module. Confirm field device polarity, loop continuity, and current loop resistance before commissioning.\u003c\/p\u003e\n\u003cp\u003eFollow the approved Trusted system hardware manual for module insertion, removal, diagnostics checking, and maintenance procedures.\u003c\/p\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":43225103237208,"sku":"T8480","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ics-triplex-t8480-analog-output-module-g51vov41ttg.png?v=1758603060","url":"https:\/\/www.industriaxplc.com\/products\/ics-triplex-t8480-analog-output-tmr-40-channel-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}