{"product_id":"ics-triplex-t8312-4c-expander-interface-adapter","title":"ICS Triplex T8312-4C Expander Interface Adapter","description":"\u003ch2\u003eICS Triplex T8312-4C Expander Interface Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for processor expansion interface functions in the ICS Triplex Trusted system, the \u003cstrong\u003eICS Triplex T8312-4C\u003c\/strong\u003e (\u003cstrong\u003eT8312\u003c\/strong\u003e Expander Interface Adapter) provides the physical and electrical interface required for communication between Trusted processor and expander hardware.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8312-4C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eT8312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExpander Interface Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13 x 8.2 x 4.5 cm estimated shipping size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC @ 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTrusted TMR and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe T8312-4C operates as an interface component within the ICS Triplex Trusted architecture. The adapter supports the physical interconnection required by the Trusted processor expansion arrangement.\u003c\/p\u003e\n\u003cp\u003eIn addition, the specified 500 VDC isolation separates the relevant electrical domains. Therefore, installation should preserve the intended isolation boundary and avoid unintended conductive paths through wiring, mounting hardware, or external interfaces.\u003c\/p\u003e\n\u003cp\u003eThe Trusted platform uses triple modular redundancy (TMR) for high-integrity control processing. However, the supplied data does not specify a separate SIL certification rating or a particular 2oo3 function for the T8312-4C itself. Such system-level characteristics should therefore be verified against the applicable Trusted system documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What supply does the T8312-4C require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified supply is 5 VDC at 200 mA, with typical power consumption below 1 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical isolation does the T8312-4C provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification lists 500 VDC isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the T8312-4C operate in high-humidity environments?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified operating humidity is 5 to 95 % RH, non-condensing. Condensation should not occur during operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the T8312-4C according to the applicable Trusted system hardware documentation and approved cabinet layout.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 5 VDC supply before connecting the adapter.\u003c\/li\u003e\n\u003cli\u003eKeep interface wiring separated from high-voltage and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified isolation boundary during cabinet wiring.\u003c\/li\u003e\n\u003cli\u003eSecure connectors and cables to prevent mechanical loading on the interface assembly.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring to minimize electromagnetic coupling from power circuits.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cabinet grounding and bonding practices for the complete Trusted system.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified operating temperature or humidity range.\u003c\/li\u003e\n\u003cli\u003eInspect connectors and mating interfaces for contamination or mechanical damage before installation.\u003c\/li\u003e\n\u003cli\u003eDo not apply power until the wiring and interface connections have been verified.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44547491004504,"sku":"T8312-4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/T8312-4C-3_1200x1200_f9ae7187-2ad1-4345-a85d-bec8371ff5e6.jpg?v=1786349816","url":"https:\/\/www.industriaxplc.com\/products\/ics-triplex-t8312-4c-expander-interface-adapter","provider":"IndustriaX Limited","version":"1.0","type":"link"}