{"product_id":"ic670mdl740-ge-fanuc-field-control-discrete-output-module","title":"General Electric IC670MDL740 Field Control 16-Point Discrete Output Module","description":"\u003cp\u003eThe General Electric IC670MDL740 is a high-performance 16-point discrete output module, specifically engineered for the Field Control I\/O system. This module provides reliable positive logic (sourcing) output control for a variety of industrial automation tasks, operating within a voltage range of 10-30 VDC. It is designed to integrate seamlessly into distributed control architectures, offering efficient signal management for low-current output devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point positive logic (sourcing) discrete output channels.\u003c\/li\u003e\n\u003cli\u003eNominal operating voltage of 24 VDC with an input range of 10-30 VDC.\u003c\/li\u003e\n\u003cli\u003eMaximum load capacity of 0.5 Amps per channel, with a 4 Amp total module limit.\u003c\/li\u003e\n\u003cli\u003eIntegrated status LED indicators for each output channel to simplify diagnostics.\u003c\/li\u003e\n\u003cli\u003eCommon fuse protection for the output group, featuring a dedicated blown-fuse indicator.\u003c\/li\u003e\n\u003cli\u003eCompact, DIN-rail mountable design for space-constrained control cabinets.\u003c\/li\u003e\n\u003cli\u003eStandardized terminal base for simplified wiring and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator \u0026amp; Valve Control:\u003c\/strong\u003e Ideal for driving DC solenoids and pneumatic valve manifolds in assembly and fluid handling systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperator Interface:\u003c\/strong\u003e Powers pilot lamps, status indicators, and industrial alarms on control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Switching:\u003c\/strong\u003e Capable of driving interposing relays for higher-power AC or DC load control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Suitable for integration into packaging, textile, and conveyor sorting systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWastewater Infrastructure:\u003c\/strong\u003e Distributed architecture supports remote pump and sensor control in large-scale facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (Positive Logic\/Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Module\u003c\/td\u003e\n\u003ctd\u003e4 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e200 microseconds (0.5 A resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Draw\u003c\/td\u003e\n\u003ctd\u003e111 mA (from BIU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Capacity\u003c\/td\u003e\n\u003ctd\u003eAWG #14-22 (single); AWG #18 (dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Bus Interface Unit (BIU) is powered down before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module securely onto the designated DIN-rail, ensuring proper alignment with the terminal base.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges (AWG #14-22) and ensure terminals are tightened to manufacturer specifications to maintain contact integrity.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the module to facilitate adequate ventilation and cooling.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-voltage or high-EMI sources to minimize noise and interference.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670MDL740?\u003c\/h3\u003e\u003cp\u003eThis module acts as a 16-point sourcing output interface for the GE Field Control system, allowing the PLC to control external DC loads such as solenoids, relays, and indicators.\u003c\/p\u003e\u003ch3\u003eCan this module be used for higher current requirements?\u003c\/h3\u003e\u003cp\u003eNo, the IC670MDL740 is limited to 0.5A per point. For higher current applications, consider the IC670MDL742 (1.0A per point) or the IC670MDL730 (2.0A per point).\u003c\/p\u003e\u003ch3\u003eHow is the module protected?\u003c\/h3\u003e\u003cp\u003eThe output group is protected by a 5 Amp, 250V (5x20mm) slow-acting fuse, which includes a visual status indicator on the module faceplate.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44728121458776,"sku":"IC670MDL740","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_6094819f-0d14-449b-9587-4a919ab43286.jpg?v=1788586466","url":"https:\/\/www.industriaxplc.com\/products\/ic670mdl740-ge-fanuc-field-control-discrete-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}