{"product_id":"honeywell-tc-odj161-24-vdc-digital-output-module","title":"Honeywell TC-ODJ161 24 VDC Digital Output Module","description":"\u003ch2\u003eHoneywell TC-ODJ161 24 VDC Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-ODJ161\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-ODJ161\u003c\/strong\u003e 24 VDC Digital Output Module, operates as a dedicated hardware component for discrete signal execution within Honeywell Experion I\/O architectures. The module provides 16 isolated output channels for controlling external DC field loads through industrial control commands.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-ODJ161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eIsolated Discrete Output Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e30 deg C full load reference; 60 deg C reduced load condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.7 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Points\u003c\/td\u003e\n\u003ctd\u003e16 individually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 A max at 30 deg C; 1.0 A max at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Output Current\u003c\/td\u003e\n\u003ctd\u003e8.0 A max at 30 deg C; 4.0 A max at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current Capability\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms, repeatable every 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum On-State Current\u003c\/td\u003e\n\u003ctd\u003e1.0 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.2 VDC at 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Delay\u003c\/td\u003e\n\u003ctd\u003eOff to On: 1.0 ms max; On to Off: 2.0 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS output to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH 36-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell control rack and I\/O subsystem mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe TC-ODJ161 uses channel-to-channel isolation to separate field output circuits from the control backplane. This electrical design limits interference transfer between connected loads and supports direct switching of 24 VDC devices.\u003c\/p\u003e\n\u003cp\u003eMoreover, Honeywell I\/O modules within Experion architectures commonly integrate with process control signal paths including 4-20 mA HART loop protocol, FOUNDATION Fieldbus, and Profibus PA interfaces through dedicated I\/O modules. The TC-ODJ161 performs discrete output execution rather than analog measurement or fieldbus signal processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many discrete output channels are available on the TC-ODJ161?\u003cbr\u003eA: The module provides 16 individually isolated 24 VDC discrete output channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum output current capability of each channel?\u003cbr\u003eA: Each output channel supports up to 2.0 A at 30 deg C and 1.0 A at 60 deg C operating conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation rating is provided between the output circuits and backplane?\u003cbr\u003eA: The module provides 1500 VAC RMS isolation between the output side and the control backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TC-ODJ161 in the designated Honeywell I\/O rack position according to system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eUse the specified TC-TBCH terminal block for field wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify external load current requirements before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eMaintain correct DC polarity during field cable termination.\u003c\/li\u003e\n\u003cli\u003eSeparate high-current switching wiring from low-level signal cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm module status indicators and controller configuration after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44349961633880,"sku":"TC-ODJ161","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-ODJ161-3.jpg?v=1783585154","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-tc-odj161-24-vdc-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}