{"product_id":"honeywell-tc-oah061-analog-output-module","title":"Honeywell TC-OAH061 | Analog Output Module","description":"\u003ch2\u003eHoneywell TC-OAH061 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-OAH061\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-OAH061\u003c\/strong\u003e analog output module, operates as a dedicated hardware component for 4-20 mA current loop signal generation within the Experion PKS \/ C200 control I\/O architecture. Configured for deterministic analog output execution in distributed control systems, the \u003cstrong\u003eHoneywell TK-OAH061\u003c\/strong\u003e (\u003cstrong\u003eTC-OAH061\u003c\/strong\u003e analog output module) provides direct electrical conversion of controller-side digital values into field-level current loop outputs.\u003c\/p\u003e\n\u003cp\u003eThe module implements 6 independent galvanically isolated output channels, each supporting 4-20 mA signal driving with high-resolution digital-to-analog conversion and channel separation for loop integrity preservation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-OAH061 \/ TC-OAH061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg to 0.5 kg (module only, nominal range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUp to 6.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 isolated output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (0-21 mA operational range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit D\/A conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Channel Isolation \u0026amp; 4-20 mA Loop Execution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module implements per-channel galvanic isolation architecture, ensuring electrical decoupling between output loops and system-side electronics. Each channel operates as an independent current sourcing node for 4-20 mA loop transmission, supporting direct actuator, valve positioner, and drive interface loading without shared electrical reference coupling. The 13-bit conversion structure distributes resolution across the full current span, allowing stable incremental loop adjustment under continuous control updates at a 25 ms system cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TK-OAH061 support hot-swap insertion under energized backplane conditions?\u003cbr\u003eA: Hot-swap capability is dependent on the C200 backplane implementation. The module itself is designed for controlled system insertion but requires compliance with system-level power isolation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of channel isolation on cross-channel loop interference?\u003cbr\u003eA: Each output channel is galvanically isolated, preventing direct electrical coupling between 4-20 mA loops and reducing cross-channel leakage paths at the hardware level.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware-level calibration required after module replacement?\u003cbr\u003eA: Calibration behavior is managed at controller configuration level. The module itself does not contain field-updatable firmware logic exposed to end-user adjustment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module into the designated C200 I\/O rack slot with backplane power fully verified prior to insertion. Maintain shield continuity for each 4-20 mA loop and ensure single-point grounding at the control cabinet earth reference. Field wiring should be separated from high-voltage or switching conductors to preserve current loop stability. Terminal block engagement must be fully seated to maintain channel isolation integrity and prevent intermittent loop discontinuities.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44296186200152,"sku":"TK-OAH061","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK-OAH061-3.jpg?v=1782809235","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-tc-oah061-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}