{"product_id":"honeywell-tc-oah061-analog-output-module-1","title":"Honeywell TC-OAH061 Analog Output Module","description":"\u003ch2\u003eHoneywell TC-OAH061 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated analog current signal execution in Honeywell Experion Series I\/O architectures, the \u003cstrong\u003eHoneywell TC-OAH061\u003c\/strong\u003e (\u003cstrong\u003eTC-OAH061\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution for 4-20 mA field output circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-OAH061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Resolution\u003c\/td\u003e\n\u003ctd\u003e13 bits across 21 mA span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Capability\u003c\/td\u003e\n\u003ctd\u003e20.0 mA maximum into loads of 500 ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.1% of range from 4.0 mA to 21.0 mA at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003eLess than 2 ms to 95% final value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e24 VAC\/VDC continuous at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic current limiting to 21 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eLess than 2.0% error at 10 V\/m, 27 to 1000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Offset Drift\u003c\/td\u003e\n\u003ctd\u003e1 uA\/deg C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift\u003c\/td\u003e\n\u003ctd\u003e60 ppm\/deg C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2546 VDC tested for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser to System Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2546 VDC tested for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH 20-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 6.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Process Signal Isolation and DCS Interface\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-OAH061 is designed for analog output execution within Honeywell Experion control platforms. Each of the six channels provides galvanically isolated 4-20 mA current output for connection to control valves, actuators, and other analog field devices.\u003c\/p\u003e\n\u003cp\u003eThe module architecture includes channel-to-channel isolation to reduce electrical interaction between independent field loops. Moreover, the output circuitry provides electronic short circuit limiting and continuous overvoltage protection for connected field circuits.\u003c\/p\u003e\n\u003cp\u003eThe TC-OAH061 supports direct integration with process instrumentation using standard 4-20 mA loop interfaces. The isolated output design maintains signal separation between the control system backplane and external field wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog output channels are available on the Honeywell TC-OAH061?\u003cbr\u003eA: The TC-OAH061 provides six independent galvanically isolated analog output channels.\u003c\/p\u003e\n\u003cp\u003eQ: What output signal range is supported by the TC-OAH061?\u003cbr\u003eA: The module provides a 0 to 21.0 mA output range with 13-bit current resolution, supporting standard 4-20 mA process loops.\u003c\/p\u003e\n\u003cp\u003eQ: What terminal connection hardware is required for the TC-OAH061?\u003cbr\u003eA: The module uses the Honeywell TC-TBNH 20-position terminal block for field wiring connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TC-OAH061 in the designated Honeywell Experion I\/O rack position according to the system hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify terminal block compatibility before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal cables from high-voltage power conductors to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard and avoid multiple grounding points on signal shields.\u003c\/li\u003e\n\u003cli\u003eConfirm field device loop polarity before applying power to the analog output circuits.\u003c\/li\u003e\n\u003cli\u003eCheck output loop resistance and actuator input requirements before commissioning.\u003c\/li\u003e\n\u003cli\u003ePerform insulation and wiring verification before enabling process control outputs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44349972775000,"sku":"TC-OAHO61","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-OAHO61.jpg?v=1783585328","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-tc-oah061-analog-output-module-1","provider":"IndustriaX Limited","version":"1.0","type":"link"}