{"product_id":"honeywell-tc-oah061-96978274-a01-analog-output-module","title":"Honeywell TC-OAH061 96978274-A01 Analog Output Module","description":"\u003ch2\u003eHoneywell TC-OAH061 96978274-A01 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-OAH061 96978274-A01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-OAH061\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for isolated analog current signal generation within Honeywell Experion Series-A I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-OAH061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e96978274-A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion Series-A I\/O system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e96 x 96 x 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 6.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Resolution\u003c\/td\u003e\n\u003ctd\u003e13 bits across 21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e2546 VDC, tested for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-to-System Isolation\u003c\/td\u003e\n\u003ctd\u003e2546 VDC, tested for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003e24 VAC\/VDC continuous overvoltage protection at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eError less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH 20-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Signal Isolation and DCS Interface\u003c\/h3\u003e\n\u003cp\u003eThe TC-OAH061 applies Honeywell process control I\/O design principles for analog loop execution. The module provides six isolated 4-20 mA output channels for actuator commands, valve positioning loops, and analog control devices.\u003c\/p\u003e\n\u003cp\u003eMoreover, the galvanic isolation architecture separates field output circuits from system electronics. This configuration limits signal interference between channels and supports stable analog transmission in DCS environments.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for process instrumentation interfaces where channel-to-channel isolation and controlled current output behavior are required. It supports analog output functions commonly associated with Honeywell Experion Series-A I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output signal does the TC-OAH061 provide?\u003c\/strong\u003e\u003cbr\u003eA: The TC-OAH061 provides six analog current outputs with a 0 to 21.0 mA operating range, including the standard 4-20 mA process signal range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide electrical isolation between output channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The TC-OAH061 uses galvanically isolated output channels and provides channel-to-channel and user-to-system isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal block is required for field wiring connection?\u003c\/strong\u003e\u003cbr\u003eA: The module connects through the Honeywell TC-TBNH 20-position terminal block for field signal termination.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TC-OAH061 module in the designated Honeywell Experion Series-A I\/O rack position according to system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify terminal assignments before connecting field analog loops.\u003c\/li\u003e\n\u003cli\u003eUse shielded cable for low-level analog signal wiring in areas with electromagnetic interference sources.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding practice to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eConfirm controller configuration matches the assigned output channel settings before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck loop current values and field device response during startup verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44349940170840,"sku":"TC-OAH061 96978274-A01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-OAH06196978274-A01-3.jpg?v=1783584828","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-tc-oah061-96978274-a01-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}