{"product_id":"honeywell-tc-fxx102-experion-series-a-10-slot-chassis","title":"Honeywell TC-FXX102 Experion Series-A 10 Slot Chassis","description":"\u003ch2\u003eHoneywell TC-FXX102 Experion Series-A 10 Slot Chassis\u003c\/h2\u003e\n\u003cp\u003eConfigured for module mounting and multi-voltage backplane power distribution in Honeywell Experion Series-A CIOM-A platforms, the \u003cstrong\u003eHoneywell TC-FXX102\u003c\/strong\u003e (\u003cstrong\u003eTC-FXX102\u003c\/strong\u003e 10 Slot Chassis) provides direct physical power and communication infrastructure for installed I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-FXX102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e10 Slot Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series-A Chassis I\/O Module (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26.3 x 116.9 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e10 Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Current Rating\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Backplane Voltage\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum 5.1 V Backplane Current\u003c\/td\u003e\n\u003ctd\u003eUp to 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Backplane Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum 24 V Backplane Current\u003c\/td\u003e\n\u003ctd\u003eUp to 2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Backplane Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum 3.3 V Backplane Current\u003c\/td\u003e\n\u003ctd\u003eUp to 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Combined Backplane Output Power\u003c\/td\u003e\n\u003ctd\u003e75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by installed Series-A modules, maximum backplane output limited to 75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Backplane and Signal Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-FXX102 chassis provides a multi-rail backplane architecture for Experion Series-A I\/O modules. The backplane distributes 5.1 VDC logic power, 24 VDC auxiliary power, and 3.3 VDC I\/O power to installed modules.\u003c\/p\u003e\n\u003cp\u003eThe chassis supports Honeywell Series-A communication and I\/O module integration through dedicated backplane connections. Channel-to-channel isolation and signal integrity depend on the installed I\/O module design, while the chassis provides the physical electrical interface required for module operation.\u003c\/p\u003e\n\u003cp\u003eThe chassis configuration supports process control architectures where modules require stable backplane voltage distribution and structured I\/O density scaling. In addition, the design allows integration of redundant power supply arrangements using compatible redundant power supply adapters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many modules can be installed in the TC-FXX102 chassis?\u003cbr\u003eA: The chassis provides 10 single-wide module slots. Double-wide modules occupy two adjacent slot positions.\u003c\/p\u003e\n\u003cp\u003eQ: What backplane voltages are distributed by the TC-FXX102?\u003cbr\u003eA: The chassis distributes three backplane voltage rails: 5.1 VDC logic power, 24 VDC auxiliary power, and 3.3 VDC I\/O power.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TC-FXX102 support redundant power configurations?\u003cbr\u003eA: Yes. The chassis supports redundant power configurations through compatible TC-RPSCA2 or TK-RPSCA2 redundant power supply chassis adapters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the TC-FXX102 chassis on a mechanically stable panel surface with sufficient clearance for module insertion, wiring access, and thermal ventilation.\u003c\/p\u003e\n\u003cp\u003eVerify that the installed power supply configuration matches the Series-A chassis requirements before energizing the backplane. Ensure all module connectors are fully seated and mechanical locking features are engaged.\u003c\/p\u003e\n\u003cp\u003eRoute power and signal wiring separately where possible to reduce electrical interference. Maintain proper cabinet grounding practices, including connection of protective earth and cable shield termination according to site electrical standards.\u003c\/p\u003e\n\u003cp\u003eBefore operation, confirm the installed module combination does not exceed the chassis backplane voltage rail current limits and total output power specification.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44350000431192,"sku":"TC-FXX102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-FXX102-3.jpg?v=1783586040","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-tc-fxx102-experion-series-a-10-slot-chassis","provider":"IndustriaX Limited","version":"1.0","type":"link"}