{"product_id":"honeywell-mc-taih22-high-level-analog-input-field-termination-assembly","title":"Honeywell MC-TAIH22 High-Level Analog Input Field Termination Assembly","description":"\u003ch2\u003eHoneywell MC-TAIH22 High-Level Analog Input Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH22 51204170-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAIH22\u003c\/strong\u003e High-Level Analog Input Field Termination Assembly, operates as a dedicated hardware component for analog signal conditioning and acquisition within Honeywell Process Manager and Experion PKS I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH22 51204170-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Input Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 VDC, 1-5 VDC high-level analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eCompression screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system electrical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eAvailable depending on hardware revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail or Honeywell cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 cm x 12.7 cm x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eField termination assembly power consumption based on system I\/O configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Conditioning and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIH22 processes high-level analog field signals before transmission to Honeywell Process Manager and Experion PKS control platforms. The assembly accepts standard transmitter outputs, including 4-20 mA current loops and voltage inputs, then performs signal termination, filtering, and electrical isolation.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control applications, the module supports channel-to-channel isolation principles to reduce interference between independent field loops. Additionally, the hardware configuration allows integration with analog measurement devices using HART-based 4-20 mA loop communication when the connected I\/O architecture supports transmitter communication functions.\u003c\/p\u003e\n\u003cp\u003eThe module design supports stable analog acquisition for variables such as pressure, temperature, flow, and level measurement. Therefore, proper shielding, grounding, and signal routing practices directly affect measurement quality in industrial installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MC-TAIH22 support direct connection of 4-20 mA transmitters?\u003cbr\u003eA: Yes. The assembly supports high-level analog inputs from 4-20 mA transmitters and other compatible voltage signal sources through its field termination channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-TAIH22 provide electrical isolation between field channels and the control system?\u003cbr\u003eA: Yes. The module provides channel-to-system electrical isolation for connected analog signal paths.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MC-TAIH22 be installed as a standalone analog input controller?\u003cbr\u003eA: No. The MC-TAIH22 functions as a field termination assembly and requires connection to the corresponding Honeywell Process Manager or Experion PKS I\/O hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MC-TAIH22 inside the specified Honeywell cabinet or approved DIN rail mounting location.\u003c\/li\u003e\n\u003cli\u003eConnect analog field wiring using shielded instrumentation cables where required by the installation design.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the site grounding standard to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eVerify field loop polarity before applying system power.\u003c\/li\u003e\n\u003cli\u003eConfirm the configured input type matches the connected transmitter output range before commissioning.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections periodically to maintain proper mechanical contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44485445681240,"sku":"MC-TSIA12 51303932-478","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-TSIA1251303932-478-3.jpg?v=1785496360","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-mc-taih22-high-level-analog-input-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}