{"product_id":"honeywell-mc-taih03-high-level-analog-input-field-termination-assembly","title":"Honeywell MC-TAIH03 High-Level Analog Input Field Termination Assembly","description":"\u003ch2\u003eHoneywell MC-TAIH03 High-Level Analog Input Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH03 (51309136-175)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAIH03\u003c\/strong\u003e High-Level Analog Input Field Termination Assembly, operates as a dedicated hardware component for analog signal termination and conditioning within Honeywell TDC 3000 and Experion PKS I\/O subsystems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH03 (51309136-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Field Termination Assembly (HLAI FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, APM, HPM, Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003eField transmitter signal termination and conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew\/compression terminal assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eCabinet or DIN rail mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Analog Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIH03 processes field-level analog transmitter connections and transfers conditioned signals to Honeywell I\/O processor modules. It supports standard process measurement loops using 4-20 mA and 1-5 V DC input signals.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module supports process control architectures that use 4-20 mA HART loop protocol through compatible field instrumentation configurations. Channel-to-channel isolation and signal conditioning functions depend on the associated Honeywell I\/O processor and field wiring arrangement.\u003c\/p\u003e\n\u003cp\u003eThe FTA provides organized termination points for analog field wiring. Therefore, technicians can perform channel identification, loop verification, and maintenance operations directly at the cabinet interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals does the MC-TAIH03 accept?\u003cbr\u003eA: The MC-TAIH03 accepts high-level analog input signals including 4-20 mA DC and 1-5 V DC transmitter signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MC-TAIH03 operate as a standalone analog input controller?\u003cbr\u003eA: No. The MC-TAIH03 functions as a field termination assembly and requires connection to compatible Honeywell I\/O processor hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-TAIH03 support direct field device calibration?\u003cbr\u003eA: The assembly provides signal termination functions. Calibration procedures depend on the connected transmitter and Honeywell control system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MC-TAIH03 inside the designated control cabinet using the approved mounting arrangement. Verify terminal assignments before connecting field conductors.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cable for analog signal wiring where required by the control system design. Connect cable shields according to the site grounding standard and avoid routing analog signal cables parallel to high-voltage power conductors.\u003c\/p\u003e\n\u003cp\u003eConfirm loop polarity, signal range selection, and transmitter wiring before system commissioning. Check terminal tightness and verify that field wiring does not introduce unwanted electrical noise or ground loops.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44494964097112,"sku":"MC-TAIH03 51309136-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-TAIH03-51309136-175-3_1200x1200_3eca180d-3489-4abb-b71e-5b5ffa88f26c.jpg?v=1785751566","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-mc-taih03-high-level-analog-input-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}