{"product_id":"honeywell-mc-iolm02-standard-i-o-link-extender-card","title":"Honeywell MC-IOLM02 Standard I\/O Link Extender Card","description":"\u003ch2\u003eHoneywell MC-IOLM02 Standard I\/O Link Extender Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-IOLM02 51304419-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-IOLM02\u003c\/strong\u003e Standard I\/O Link Extender Card, operates as a dedicated hardware component for extending I\/O link communication paths within Honeywell Experion PKS, TPS, and HPM system architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-IOLM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304419-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O Link Extender Card (Main Location)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS, TPS, HPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eExtends I\/O link communication between controller locations and remote I\/O card assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.8 cm x 31.8 cm x 27.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.58 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eStandard conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell I\/O rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSupports redundant I\/O link configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Function\u003c\/td\u003e\n\u003ctd\u003eSupports hot-swappable operation in compatible racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Control Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MC-IOLM02 extends Honeywell I\/O link communication paths between local controller assemblies and remote I\/O locations. Therefore, the module maintains the electrical interface required for distributed I\/O architectures in Experion PKS, TPS, and HPM environments.\u003c\/p\u003e\n\u003cp\u003eThe module uses conformal coating protection to reduce exposure effects from humidity, industrial dust, and corrosive gases such as H2S. Additionally, the coated PCB construction supports operation in process control areas where airborne contaminants may affect unprotected electronic assemblies.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control networks, the I\/O link extender design maintains signal transmission between I\/O processing hardware and field interface modules. The module supports channel separation requirements within distributed control installations and integrates with redundant I\/O configurations where continuous communication paths are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MC-IOLM02 51304419-150 operate in redundant I\/O link configurations?\u003cbr\u003eA: Yes. The module supports redundant I\/O link configurations when installed within compatible Honeywell system architectures. The actual redundancy behavior depends on the rack configuration and controller design.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-IOLM02 support online replacement?\u003cbr\u003eA: The module supports hot-swappable operation in compatible Honeywell racks. Maintenance personnel must verify rack conditions and system procedures before removing or inserting the card.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection does the MC-IOLM02 provide?\u003cbr\u003eA: The module uses standard conformal coating on the circuit board to protect electronic components from humidity, dust, and corrosive industrial contaminants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the MC-IOLM02 in the designated Honeywell I\/O rack position according to the system hardware configuration manual.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power status and module insertion procedure comply with Honeywell maintenance requirements before replacement activities.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding between the rack assembly and control cabinet protective earth connection to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eRoute I\/O communication cables separately from high-voltage power wiring and high-current switching circuits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eInspect connectors, backplane contacts, and cable shields before installation to confirm clean mechanical and electrical connections.\u003c\/li\u003e\n\u003cli\u003eConfirm module compatibility with the target Experion PKS, TPS, or HPM system revision before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44494862811224,"sku":"MC-IOLM02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-IOLM02-3_1200x1200_fc18fab7-bbe8-446e-84c8-9adbf56a769d.jpg?v=1785749497","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-mc-iolm02-standard-i-o-link-extender-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}